<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>Volumen 21</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/137770</link>
<description/>
<pubDate>Wed, 25 Nov 2026 11:59:37 GMT</pubDate>
<dc:date>2026-11-25T11:59:37Z</dc:date>
<item>
<title>Generación fotovoltaica distribuida y redes inteligentes en la localidad de Centenario, provincia del Neuquén: Primeras etapas del proyecto</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140944</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
El proyecto “Generación foto voltaica distribuida y redes inteligentes en la localidad de Centenario, Provincia del Neuquén.”, parcialmente financiado con Fondos Sectoriales (FONARSEC) del Ministerio de Ciencia, Tecnología e Innovación Productiva, se encuentra en ejecución desde fines de 2015 a través del CAPP IRESUD-RI, conformado por la Universidad Nacional de San Martín (UNSAM), el Ente Provincial de Energía del Neuquén (EPEN) y la empresa Aldar S.A.. Cuenta, asimismo, con la participación del Departamento Energía Solar de la CNEA. El proyecto prevé la instalación de sistemas fotovoltaicos distribuidos, con una potencia total de alrededor de 200 kW, conectados a la red de distribución eléctrica bajo una subestación transformadora de 500 kVA. En este trabajo, se presenta el estado de avance del proyecto, en particular en lo referente a la selección del sitio, el modelado del sistema de distribución y el diseño de los sistemas fotovoltaicos. Asimismo, se realiza un análisis preliminar de las externalidades del proyecto.; The project "Distributed photovoltaic generation and smart grid in the town of Centenario, Province of Neuquén," partially financed with Sectoral Funds (FONARSEC) of the Ministry of Science, Technology and Productive Innovation, is being implemented since the end of 2015 through the Consortium IRESUD-RI, formed by the National University of San Martín (UNSAM), the Provincial Energy Entity of Neuquén (EPEN) and the company Aldar S.A.. The Solar Energy Department of the Argentine Atomic Energy Commission (CNEA) is also participating. The project entails the installation of distributed photovoltaic systems with a total capacity of approximately 200 kW, connected to the electrical distribution network via a 500 kVA transformer substation. In this document, the state of progress of the project is presented, particularly regarding site selection, modeling of the distribution system and design of photovoltaic systems. Also, a preliminary analysis of the project's externalities is carried out.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140944</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>El proyecto “Generación foto voltaica distribuida y redes inteligentes en la localidad de Centenario, Provincia del Neuquén.”, parcialmente financiado con Fondos Sectoriales (FONARSEC) del Ministerio de Ciencia, Tecnología e Innovación Productiva, se encuentra en ejecución desde fines de 2015 a través del CAPP IRESUD-RI, conformado por la Universidad Nacional de San Martín (UNSAM), el Ente Provincial de Energía del Neuquén (EPEN) y la empresa Aldar S.A.. Cuenta, asimismo, con la participación del Departamento Energía Solar de la CNEA. El proyecto prevé la instalación de sistemas fotovoltaicos distribuidos, con una potencia total de alrededor de 200 kW, conectados a la red de distribución eléctrica bajo una subestación transformadora de 500 kVA. En este trabajo, se presenta el estado de avance del proyecto, en particular en lo referente a la selección del sitio, el modelado del sistema de distribución y el diseño de los sistemas fotovoltaicos. Asimismo, se realiza un análisis preliminar de las externalidades del proyecto.

The project "Distributed photovoltaic generation and smart grid in the town of Centenario, Province of Neuquén," partially financed with Sectoral Funds (FONARSEC) of the Ministry of Science, Technology and Productive Innovation, is being implemented since the end of 2015 through the Consortium IRESUD-RI, formed by the National University of San Martín (UNSAM), the Provincial Energy Entity of Neuquén (EPEN) and the company Aldar S.A.. The Solar Energy Department of the Argentine Atomic Energy Commission (CNEA) is also participating. The project entails the installation of distributed photovoltaic systems with a total capacity of approximately 200 kW, connected to the electrical distribution network via a 500 kVA transformer substation. In this document, the state of progress of the project is presented, particularly regarding site selection, modeling of the distribution system and design of photovoltaic systems. Also, a preliminary analysis of the project's externalities is carried out.</dc:description>
</item>
<item>
<title>Optimización de instalaciones fotovoltaicas para generación distribuida</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140940</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
Este trabajo presenta un estudio llevado a cabo en el Laboratorio de Ensayos y Desarrollos Energéticos (LEyDE) de la Universidad Nacional de Mar del Plata que, mediante simulación, analiza para la superficie de azotea de la Facultad de Ingeniería, cuál es la configuración más adecuada respecto de la separación de paneles e inclinación, y la influencia en la generación del sombreamiento de manera de maximizar la producción energética por metro cuadrado de terraza y de panel. Los resultados arrojan que la inclinación óptima para la zona en estudio es de 30° y que con una separación de 2,55 metros se obtiene la mayor producción por metro cuadrado de terraza y panel.; This paper presents a study developed by Laboratorio de Ensayos y Desarrollos Energéticos (LEyDE) of the National University of Mar del Plata that, through simulation, analyzes the most appropriate configuration of photovoltaic installations on the roof of the Faculty of Engineering, (the separation of panels and inclination) and the influence of shading in order to maximize energy production per m² of terrace and m² of panel. The results show that the most optimum tilt for the area under study is 30° and that with a separation of 2,55 m the highest production per m² of terrace and panel is obtained.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140940</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>Este trabajo presenta un estudio llevado a cabo en el Laboratorio de Ensayos y Desarrollos Energéticos (LEyDE) de la Universidad Nacional de Mar del Plata que, mediante simulación, analiza para la superficie de azotea de la Facultad de Ingeniería, cuál es la configuración más adecuada respecto de la separación de paneles e inclinación, y la influencia en la generación del sombreamiento de manera de maximizar la producción energética por metro cuadrado de terraza y de panel. Los resultados arrojan que la inclinación óptima para la zona en estudio es de 30° y que con una separación de 2,55 metros se obtiene la mayor producción por metro cuadrado de terraza y panel.

This paper presents a study developed by Laboratorio de Ensayos y Desarrollos Energéticos (LEyDE) of the National University of Mar del Plata that, through simulation, analyzes the most appropriate configuration of photovoltaic installations on the roof of the Faculty of Engineering, (the separation of panels and inclination) and the influence of shading in order to maximize energy production per m² of terrace and m² of panel. The results show that the most optimum tilt for the area under study is 30° and that with a separation of 2,55 m the highest production per m² of terrace and panel is obtained.</dc:description>
</item>
<item>
<title>Análisis del primer año de funcionamiento del sistema fotovoltaico conectado a la red en Base Marambio, Antártida</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140939</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
En el marco del proyecto IRESUD, en diciembre de 2014 se instaló un sistema fotovoltaico de 1,92 kWp conectado a la red eléctrica de 220 V de la Base Marambio, Antártida. En el presente trabajo se analiza el recurso solar del lugar y se muestran los resultados del primer año de generación de la instalación. Finalmente se compara el funcionamiento de la instalación con una instalación de similares características situada en la ciudad de Buenos Aires. En base a estos análisis y comparación se concluye que la utilización de este tipo de tecnologías en las bases antárticas es altamente factible, pero que se requiere combinarla con otras fuentes de generación renovables en los meses invernales.; Within the framework of the IRESUD Project, a new 1.92 kWp photovoltaic system was installed in December 2014, connected to the 220V electric network at Marambio Base, Antartida. This paper analyses the solar resources at that location and shows the results of the first year of electricity generation from this installation. Finally, we compare the working of this installation to that of one with similar characteristics in the city of Buenos Aires. Based on this analysis and comparison, we conclude that the use of this kind of technology in Antarctic bases is highly feasible, but that it needs to be combined with other renewable sources during the winter months.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140939</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>En el marco del proyecto IRESUD, en diciembre de 2014 se instaló un sistema fotovoltaico de 1,92 kWp conectado a la red eléctrica de 220 V de la Base Marambio, Antártida. En el presente trabajo se analiza el recurso solar del lugar y se muestran los resultados del primer año de generación de la instalación. Finalmente se compara el funcionamiento de la instalación con una instalación de similares características situada en la ciudad de Buenos Aires. En base a estos análisis y comparación se concluye que la utilización de este tipo de tecnologías en las bases antárticas es altamente factible, pero que se requiere combinarla con otras fuentes de generación renovables en los meses invernales.

Within the framework of the IRESUD Project, a new 1.92 kWp photovoltaic system was installed in December 2014, connected to the 220V electric network at Marambio Base, Antartida. This paper analyses the solar resources at that location and shows the results of the first year of electricity generation from this installation. Finally, we compare the working of this installation to that of one with similar characteristics in the city of Buenos Aires. Based on this analysis and comparison, we conclude that the use of this kind of technology in Antarctic bases is highly feasible, but that it needs to be combined with other renewable sources during the winter months.</dc:description>
</item>
<item>
<title>Estudio tarifario para el mercado disperso de la provincia de Catamarca</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140935</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
El presente trabajo muestra el resumen de una metodología para la determinación de tarifas del mercado  disperso  de la provincia de Catamarca.  En  primer lugar se efectúa una caracterización del mercado disperso, satisfecho y potencial. A posteriori, a partir de un estudio exploratorio en otras provincias con experiencia en la temática, se establecen aspectos relevantes de componentes de costos y operatoria del mantenimiento de las instalaciones. En función a lo analizado se propone un cuadro tarifario para sistemas individuales del mercado disperso. Se analizó además la incidencia de los costos de mantenimiento en la tarifa de los usuarios residenciales individuales. El estudio tarifario ofrecerá una propuesta de tarifas diferenciadas para sistemas con fuentes renovables.; The present work shows the summary of a methodology for determining the dispersed market rates of the province of Catamarca. In the first place a characterization of the dispersed, satisfied and potential market is carried out. A posteriori, based on an exploratory study in other provinces with experience in the subject, establishes relevant aspects of cost components and operation of the maintenance of the facilities. According to the analyzed, a tariff table is proposed for individual systems of the dispersed market. The incidence of maintenance costs in the rate of individual residential users was also analyzed. The tariff study will offer a proposal of differentiated tariffs for systems with renewable sources.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140935</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>El presente trabajo muestra el resumen de una metodología para la determinación de tarifas del mercado  disperso  de la provincia de Catamarca.  En  primer lugar se efectúa una caracterización del mercado disperso, satisfecho y potencial. A posteriori, a partir de un estudio exploratorio en otras provincias con experiencia en la temática, se establecen aspectos relevantes de componentes de costos y operatoria del mantenimiento de las instalaciones. En función a lo analizado se propone un cuadro tarifario para sistemas individuales del mercado disperso. Se analizó además la incidencia de los costos de mantenimiento en la tarifa de los usuarios residenciales individuales. El estudio tarifario ofrecerá una propuesta de tarifas diferenciadas para sistemas con fuentes renovables.

The present work shows the summary of a methodology for determining the dispersed market rates of the province of Catamarca. In the first place a characterization of the dispersed, satisfied and potential market is carried out. A posteriori, based on an exploratory study in other provinces with experience in the subject, establishes relevant aspects of cost components and operation of the maintenance of the facilities. According to the analyzed, a tariff table is proposed for individual systems of the dispersed market. The incidence of maintenance costs in the rate of individual residential users was also analyzed. The tariff study will offer a proposal of differentiated tariffs for systems with renewable sources.</dc:description>
</item>
<item>
<title>Projeto sol e água no sertão: processo de implantação e avaliação de um sistema de bombeamento fotovoltaico para irrigação de uso familiar no semiárido brasileiro</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140933</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
O presente artigo  apresenta os principáis resultados da implantado  e avaliagáo  de um sistema fotovoltaico  de bombeamento  para irrigado  de uso  familiar no  Semiárido  piauiense.  O diferencial desse projeto  é a utilizado  de um dispositivo  de fabricado  nacional (brasileira) para acoplar o  gerador fotovoltaico  a urna motobomba nacional trifásica,  barateando  o  sistema e facilitando a manutengáo  e troca dos equipamentos.  Ao  longo  dos cinco  anos em que o  projeto  foi avaliado  o sistema apresentou-se robusto  e técnicamente confiável.  Todavía,  aspectos nao  técnicos relacionados as peculiaridades locáis surgiram como  barreiras a essa iniciativa,  evidenciando  a complexidade de empreendimentos dessa natureza em comunidades rurais dispersas; This article presents the main results of the implementation and evaluation of a photovoltaic pumping system for irrigation in family farming Piauí semiarid. The differential of this project is the use of a national system for attaching photovoltaic panels to a three-phase national pump, reducing the system and facilitating maintenance and replacement of equipment. Over the three years in which the system was evaluated the system was robust and technically reliable. However, non-technical aspects related to local peculiarities emerged as barriers to this initiative, high lighting the complexity of projects of this nature in scattered rural communities.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140933</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>O presente artigo  apresenta os principáis resultados da implantado  e avaliagáo  de um sistema fotovoltaico  de bombeamento  para irrigado  de uso  familiar no  Semiárido  piauiense.  O diferencial desse projeto  é a utilizado  de um dispositivo  de fabricado  nacional (brasileira) para acoplar o  gerador fotovoltaico  a urna motobomba nacional trifásica,  barateando  o  sistema e facilitando a manutengáo  e troca dos equipamentos.  Ao  longo  dos cinco  anos em que o  projeto  foi avaliado  o sistema apresentou-se robusto  e técnicamente confiável.  Todavía,  aspectos nao  técnicos relacionados as peculiaridades locáis surgiram como  barreiras a essa iniciativa,  evidenciando  a complexidade de empreendimentos dessa natureza em comunidades rurais dispersas

This article presents the main results of the implementation and evaluation of a photovoltaic pumping system for irrigation in family farming Piauí semiarid. The differential of this project is the use of a national system for attaching photovoltaic panels to a three-phase national pump, reducing the system and facilitating maintenance and replacement of equipment. Over the three years in which the system was evaluated the system was robust and technically reliable. However, non-technical aspects related to local peculiarities emerged as barriers to this initiative, high lighting the complexity of projects of this nature in scattered rural communities.</dc:description>
</item>
<item>
<title>Pobreza energética en zonas rurales de la provincia de Salta</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140930</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
En este trabajo se presenta un análisis preliminar de una forma particular de medida de pobreza energética en zonas rurales de Salta. La misma fue definida de acuerdo a condiciones específicas de la región y teniendo en cuenta el abundante recurso solar de las provincias del NOA en general y de Salta en particular. La gran mayoría de los datos corresponden al censo 2010, aunque algunos de ellos fueron calculados, deducidos o inferidos. Si bien la pobreza tiene dimensiones diversas, se explora aquí la energética. Es en esa línea argumental donde se efectúan propuestas para mitigarla. Aunque sea difícil separar la pobreza energética del problema más amplio y más complejo de la pobreza en general, está bien establecido la importancia que tiene la energía para el desarrollo. Sin embargo, muchos gobiernos ven al acceso como “tener o no tener” y no como: acceso a servicios domésticos, comunitarios y productivos.; This paper presents a preliminary analysis of a particular form of energy poverty measurement in rural areas of Salta. The same was defined according to specific conditions of the region and taking into account the abundant solar resource of the provinces of NOA in general and of Salta in particular. The great majority of the data correspond to the 2010 census, although some of them were calculated, deduced or inferred. Although poverty has different dimensions, energy is explored here. It is in this line of argument that proposals are made to mitigate it. While it is difficult to separate energy poverty from the broader and more complex problem of poverty in general, the importance of energy for development is well established. However, many governments see access as having or not having access to domestic, community and productive services.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140930</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>En este trabajo se presenta un análisis preliminar de una forma particular de medida de pobreza energética en zonas rurales de Salta. La misma fue definida de acuerdo a condiciones específicas de la región y teniendo en cuenta el abundante recurso solar de las provincias del NOA en general y de Salta en particular. La gran mayoría de los datos corresponden al censo 2010, aunque algunos de ellos fueron calculados, deducidos o inferidos. Si bien la pobreza tiene dimensiones diversas, se explora aquí la energética. Es en esa línea argumental donde se efectúan propuestas para mitigarla. Aunque sea difícil separar la pobreza energética del problema más amplio y más complejo de la pobreza en general, está bien establecido la importancia que tiene la energía para el desarrollo. Sin embargo, muchos gobiernos ven al acceso como “tener o no tener” y no como: acceso a servicios domésticos, comunitarios y productivos.

This paper presents a preliminary analysis of a particular form of energy poverty measurement in rural areas of Salta. The same was defined according to specific conditions of the region and taking into account the abundant solar resource of the provinces of NOA in general and of Salta in particular. The great majority of the data correspond to the 2010 census, although some of them were calculated, deduced or inferred. Although poverty has different dimensions, energy is explored here. It is in this line of argument that proposals are made to mitigate it. While it is difficult to separate energy poverty from the broader and more complex problem of poverty in general, the importance of energy for development is well established. However, many governments see access as having or not having access to domestic, community and productive services.</dc:description>
</item>
<item>
<title>Metodología para el trazado de las cartas solares de la Pampa Húmeda argentina</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140860</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
El creciente interés en el aprovechamiento energético de la radiación solar evidencia la necesidad de contar con cartas actualizadas de los niveles de irradiación solar a nivel de la superficie terrestre. El dimensionamiento de los sistemas de aprovechamiento en general y, en particular, de las plantas fotovoltaicas productoras de energía eléctrica, requiere de un conocimiento de la variabilidad espacio temporal del recurso. Con ese objetivo, diversas provincias argentinas han confeccionado mapas de irradiación solar o han recurrido a estimaciones realizadas con imágenes satelitales. La región de la Pampa Húmeda Argentina presenta cualidades que justifican emprendimientos de aprovechamiento de la radiación solar: niveles relativamente altos de irradiación, notable actividad económica y una gran población, además de una cantidad de redes de distribución eléctrica que resultan accesibles. El presente trabajo evalúa los requerimientos necesarios para trazar las futuras cartas de irradiación solar de esta región que el GERSolar emprenderá durante este año.; The growing interest in the energy use of solar radiation has made evident the need to have up-to-date charts of solar radiation levels at the Earth's surface. The sizing of the systems of exploitation in general and, in particular, of photovoltaic plants producing electrical energy, requires a knowledge of the variability temporal space of the solar resource. With this objective, several Argentine provinces have made maps of solar irradiation or resorted to estimates made with satellite images. The Pampa Húmeda Argentina region has several qualities that make it attractive to undertake projects to exploit the energy of solar radiation: relatively high levels of irradiation, great economic activity and the largest population in the country, and a important number of accessible electric distribution networks. The present work evaluates the necessary requirements to trace future solar irradiation charts of the area that GERSolar will undertake during the current year.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140860</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>El creciente interés en el aprovechamiento energético de la radiación solar evidencia la necesidad de contar con cartas actualizadas de los niveles de irradiación solar a nivel de la superficie terrestre. El dimensionamiento de los sistemas de aprovechamiento en general y, en particular, de las plantas fotovoltaicas productoras de energía eléctrica, requiere de un conocimiento de la variabilidad espacio temporal del recurso. Con ese objetivo, diversas provincias argentinas han confeccionado mapas de irradiación solar o han recurrido a estimaciones realizadas con imágenes satelitales. La región de la Pampa Húmeda Argentina presenta cualidades que justifican emprendimientos de aprovechamiento de la radiación solar: niveles relativamente altos de irradiación, notable actividad económica y una gran población, además de una cantidad de redes de distribución eléctrica que resultan accesibles. El presente trabajo evalúa los requerimientos necesarios para trazar las futuras cartas de irradiación solar de esta región que el GERSolar emprenderá durante este año.

The growing interest in the energy use of solar radiation has made evident the need to have up-to-date charts of solar radiation levels at the Earth's surface. The sizing of the systems of exploitation in general and, in particular, of photovoltaic plants producing electrical energy, requires a knowledge of the variability temporal space of the solar resource. With this objective, several Argentine provinces have made maps of solar irradiation or resorted to estimates made with satellite images. The Pampa Húmeda Argentina region has several qualities that make it attractive to undertake projects to exploit the energy of solar radiation: relatively high levels of irradiation, great economic activity and the largest population in the country, and a important number of accessible electric distribution networks. The present work evaluates the necessary requirements to trace future solar irradiation charts of the area that GERSolar will undertake during the current year.</dc:description>
</item>
<item>
<title>Modelos de estimativa da irradiação solar global mensal: Angstrom-Prescott e aprendizado de máquinas em Botucatu/SP/Brasil</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140859</link>
<description>Articulo
Estimation of Monthly Global Solar Irradiation by Models of Angstrom-Prescott and Machine Learning in Botucatu/SP/Brazil
Avances en Energías Renovables y Medio Ambiente; vol. 21
No presente trabalho é descrito o estudo comparativo, entre o métodos estatístico de Angstrom- Prescott (A-P)ᵐ e duas técnicas de Aprendizado de Máquina (AM) - Support Vector Machine (SVM)ᵐ e Artificial Neural Network (ANN)ᵐ, nas estimativa da irradiação solar global (H&lt;sub&gt;G&lt;/sub&gt;) mensal. A base de dados de H&lt;sub&gt;G&lt;/sub&gt; usada na modelagem foi medida no período de 1996 a 2011 em Botucatu/SP/Brasil. A equação (A-P)ᵐ obtida (H&lt;sub&gt;G&lt;/sub&gt;/H&lt;sub&gt;O&lt;/sub&gt;) =0,311+0,366*(n/N) com R²= 0,710 foi validada usando duas bases de dados: típica e atípica. Os indicativos estatísticos r e rRMSE, obtidos na comparação entre a estimativa e medida foram: r&lt;sup&gt;t&lt;/sup&gt;=r&lt;sup&gt;a&lt;/sup&gt;=0,980, rRMSE&lt;sup&gt;t&lt;/sup&gt;=3,9% e rRMSE&lt;sup&gt;a&lt;/sup&gt;=9,8%. As técnicas SVMᵐ e ANNᵐ foram treinadas em quatro combinações de entradas de variáveis meteorológicas, e validadas nas bases de dados típica e atípica. A comparação dos indicativos estatísticos mostra que: a técnica SVM possui melhor desempenho que o modelo (A-P) e a técnica ANN em estimar H&lt;sub&gt;G&lt;/sub&gt;. O modelo (A-P) possui melhor desempenho que a técnica ANN em estimar H&lt;sub&gt;G&lt;/sub&gt;.; In this paper we describe the comparative study between the Angstrom-Prescott (AP) model with two machine learning techniques [Support Vector Machine (SVM) and Artificial Neural Network (ANN)], in the estimation of monthly global solar irradiation (H&lt;sub&gt;G&lt;/sub&gt;). The H&lt;sub&gt;G&lt;/sub&gt; database used was measured in the period from 1996 to 2011 in Botucatu/SP/Brazil. The (A-P) model obtained (H&lt;sub&gt;G&lt;/sub&gt;/H&lt;sub&gt;O&lt;/sub&gt;) =0,311+0,366*(n/N), with R² =0.710 was validated using two databases: typical (t) and atypical (a). The statistical indicatives r, rRMSE, obtained in the comparison between the estimation and measurement were: r&lt;sub&gt;t&lt;/sub&gt;=r&lt;sub&gt;a&lt;/sub&gt;=0.980, rRMSE&lt;sub&gt;t&lt;/sub&gt;=3.9% and rRMSE&lt;sub&gt;a&lt;/sub&gt;=9.8%. The SVM and ANN techniques were trained in four combinations of inputs of meteorological variables and validated in the databases: typical and atypical. The comparison shows that: the SVM has better performance than the (A-P) model and the ANN in estimating H&lt;sub&gt;G&lt;/sub&gt;.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140859</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>No presente trabalho é descrito o estudo comparativo, entre o métodos estatístico de Angstrom- Prescott (A-P)ᵐ e duas técnicas de Aprendizado de Máquina (AM) - Support Vector Machine (SVM)ᵐ e Artificial Neural Network (ANN)ᵐ, nas estimativa da irradiação solar global (H&lt;sub&gt;G&lt;/sub&gt;) mensal. A base de dados de H&lt;sub&gt;G&lt;/sub&gt; usada na modelagem foi medida no período de 1996 a 2011 em Botucatu/SP/Brasil. A equação (A-P)ᵐ obtida (H&lt;sub&gt;G&lt;/sub&gt;/H&lt;sub&gt;O&lt;/sub&gt;) =0,311+0,366*(n/N) com R²= 0,710 foi validada usando duas bases de dados: típica e atípica. Os indicativos estatísticos r e rRMSE, obtidos na comparação entre a estimativa e medida foram: r&lt;sup&gt;t&lt;/sup&gt;=r&lt;sup&gt;a&lt;/sup&gt;=0,980, rRMSE&lt;sup&gt;t&lt;/sup&gt;=3,9% e rRMSE&lt;sup&gt;a&lt;/sup&gt;=9,8%. As técnicas SVMᵐ e ANNᵐ foram treinadas em quatro combinações de entradas de variáveis meteorológicas, e validadas nas bases de dados típica e atípica. A comparação dos indicativos estatísticos mostra que: a técnica SVM possui melhor desempenho que o modelo (A-P) e a técnica ANN em estimar H&lt;sub&gt;G&lt;/sub&gt;. O modelo (A-P) possui melhor desempenho que a técnica ANN em estimar H&lt;sub&gt;G&lt;/sub&gt;.

In this paper we describe the comparative study between the Angstrom-Prescott (AP) model with two machine learning techniques [Support Vector Machine (SVM) and Artificial Neural Network (ANN)], in the estimation of monthly global solar irradiation (H&lt;sub&gt;G&lt;/sub&gt;). The H&lt;sub&gt;G&lt;/sub&gt; database used was measured in the period from 1996 to 2011 in Botucatu/SP/Brazil. The (A-P) model obtained (H&lt;sub&gt;G&lt;/sub&gt;/H&lt;sub&gt;O&lt;/sub&gt;) =0,311+0,366*(n/N), with R² =0.710 was validated using two databases: typical (t) and atypical (a). The statistical indicatives r, rRMSE, obtained in the comparison between the estimation and measurement were: r&lt;sub&gt;t&lt;/sub&gt;=r&lt;sub&gt;a&lt;/sub&gt;=0.980, rRMSE&lt;sub&gt;t&lt;/sub&gt;=3.9% and rRMSE&lt;sub&gt;a&lt;/sub&gt;=9.8%. The SVM and ANN techniques were trained in four combinations of inputs of meteorological variables and validated in the databases: typical and atypical. The comparison shows that: the SVM has better performance than the (A-P) model and the ANN in estimating H&lt;sub&gt;G&lt;/sub&gt;.</dc:description>
</item>
<item>
<title>Estudio de las fracciones solares UV, PAR e IR en Luján-Pcia. de Buenos Aires</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140858</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
Se estimaron en Luján, Pcia. de Buenos Aires, las fracciones solares UV, PAR e IR. Para ello se utilizaron mediciones simultáneas de irradiancias globales total, UV y PAR registradas desde julio de 2014 a febrero de 2017. Se obtuvieron valores porcentuales de 4,6% en el UV, 43,2% en el rango PAR y 52,2% en el IR cercano para integrales horarias y para integrales diarias 4,5%, 43,1% y 52,4% en las franjas UV, PAR e IR respectivamente. Se pudo constatar para distintos tipos de cobertura de cielo variaciones en el UV de 18,7% para valores horarios y de 17% para valores diarios. En cambio, en la franja PAR las variaciones son del orden del 6% y en el IR cercano del 8%.; The UV, PAR and IR solar fractions were estimated in Luján, Province of Buenos Aires. For this purpose, simultaneous measurements of total, UV and PAR global irradiances from July 2014 to February 2017 were used. Percentage values of 4.6% in the UV, 43.2% in the PAR range and 52.2% in the near IR for hourly integrals were obtained and 4.5%, 43.1% and 52.4% in the UV, PAR and IR bands, respectively for daily integrals. In the case of UV variations of 18.7% for hourly values and 17% for daily values were found for different sky conditions. In the PAR range, the variations are of the order of 6% and in the near IR of 8%
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140858</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>Se estimaron en Luján, Pcia. de Buenos Aires, las fracciones solares UV, PAR e IR. Para ello se utilizaron mediciones simultáneas de irradiancias globales total, UV y PAR registradas desde julio de 2014 a febrero de 2017. Se obtuvieron valores porcentuales de 4,6% en el UV, 43,2% en el rango PAR y 52,2% en el IR cercano para integrales horarias y para integrales diarias 4,5%, 43,1% y 52,4% en las franjas UV, PAR e IR respectivamente. Se pudo constatar para distintos tipos de cobertura de cielo variaciones en el UV de 18,7% para valores horarios y de 17% para valores diarios. En cambio, en la franja PAR las variaciones son del orden del 6% y en el IR cercano del 8%.

The UV, PAR and IR solar fractions were estimated in Luján, Province of Buenos Aires. For this purpose, simultaneous measurements of total, UV and PAR global irradiances from July 2014 to February 2017 were used. Percentage values of 4.6% in the UV, 43.2% in the PAR range and 52.2% in the near IR for hourly integrals were obtained and 4.5%, 43.1% and 52.4% in the UV, PAR and IR bands, respectively for daily integrals. In the case of UV variations of 18.7% for hourly values and 17% for daily values were found for different sky conditions. In the PAR range, the variations are of the order of 6% and in the near IR of 8%</dc:description>
</item>
<item>
<title>Procedimento objetivo para a garantia de qualidade de dados de radiação solar</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140852</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
Se propone un procedimiento objetivo para la garantía de calidad de los datos de irradiancia solar disponibles. El trabajo establece la unión de procedimientos ya difundidos en la literatura (filtros físicos y estadísticos) - juntamente con algunos ajustes propuestos - y la utilización de procedimientos inéditos (e.g. box whiskers o diagramas de caja) en lo que se refiere a la garantía de calidad de datos solarimétricos. Para la obtención de los resultados, fue aplicado el procedimiento a datos de la red SONDA, en las estaciones Petrolina - PE y Brasilia-DF. Las dos series temporales tuvieron menos de 10% de datos rechazados de irradiancia solar en sus componentes global, directa y difusa.; In order to enable the use of reliable data, it is proposed an objective procedure for the quality assurance of solar radiation data. This work establishes the union of already diffused procedures in the literature (physical and statistical tests) – along with some adjustments – and the use of unpublished procedures in the quality assurance of solar radiation data (e.g. box whiskers). To obtain the results, the procedure was applied on data from the SONDA network, in stations located at Petrolina – PE and Brasília – DF, both at Brazil. All the time series had less than 10% of rejected solar radiation data.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140852</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>Se propone un procedimiento objetivo para la garantía de calidad de los datos de irradiancia solar disponibles. El trabajo establece la unión de procedimientos ya difundidos en la literatura (filtros físicos y estadísticos) - juntamente con algunos ajustes propuestos - y la utilización de procedimientos inéditos (e.g. box whiskers o diagramas de caja) en lo que se refiere a la garantía de calidad de datos solarimétricos. Para la obtención de los resultados, fue aplicado el procedimiento a datos de la red SONDA, en las estaciones Petrolina - PE y Brasilia-DF. Las dos series temporales tuvieron menos de 10% de datos rechazados de irradiancia solar en sus componentes global, directa y difusa.

In order to enable the use of reliable data, it is proposed an objective procedure for the quality assurance of solar radiation data. This work establishes the union of already diffused procedures in the literature (physical and statistical tests) – along with some adjustments – and the use of unpublished procedures in the quality assurance of solar radiation data (e.g. box whiskers). To obtain the results, the procedure was applied on data from the SONDA network, in stations located at Petrolina – PE and Brasília – DF, both at Brazil. All the time series had less than 10% of rejected solar radiation data.</dc:description>
</item>
<item>
<title>Aplicación de protocolos de control de calidad de datos de radiación solar medidos en Salta (Argentina)</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140850</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
En este trabajo se realiza el análisis de valores de radiación solar global medidos en la ciudad de Salta, durante el periodo 2013 a 2015. Se utiliza la metodología de control de calidad que utiliza la red BSRN. Se comparan los valores obtenidos contra valores de referencia medidos en la región de la ciudad de Salta durante las décadas de los 60s, 70s, 80s, 90s y 00s (no consecutivos). Se obtienen resultados que indican la importancia de contar con datos medidos que han sido filtrados usando criterios de Control de Calidad.; In this work the analysis of values of global solar radiation measured in the city of Salta during the period 2013 to 2015 is performed. The quality control methodology used by the BSRN network is used. The values obtained against reference values measured in the Salta region during the 60s, 70s, 80s, 90s and 00s (non-consecutive) are compared. Results are obtained indicating the importance of having measured data that have been filtered using Quality Control criteria.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140850</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>En este trabajo se realiza el análisis de valores de radiación solar global medidos en la ciudad de Salta, durante el periodo 2013 a 2015. Se utiliza la metodología de control de calidad que utiliza la red BSRN. Se comparan los valores obtenidos contra valores de referencia medidos en la región de la ciudad de Salta durante las décadas de los 60s, 70s, 80s, 90s y 00s (no consecutivos). Se obtienen resultados que indican la importancia de contar con datos medidos que han sido filtrados usando criterios de Control de Calidad.

In this work the analysis of values of global solar radiation measured in the city of Salta during the period 2013 to 2015 is performed. The quality control methodology used by the BSRN network is used. The values obtained against reference values measured in the Salta region during the 60s, 70s, 80s, 90s and 00s (non-consecutive) are compared. Results are obtained indicating the importance of having measured data that have been filtered using Quality Control criteria.</dc:description>
</item>
<item>
<title>Estimativa da radição global horária em superfície inclinada para o município de Botucatu/SP/Brasil usando modelo estatístico e arquiteturas de redes neurais artificiais MLP e GRNN</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140839</link>
<description>Articulo
Estimation of hourly global solar irradiation in inclined surface for the Botucatu city in SP / Brazil using statistical model and artificial neural network architectures MLP and GRNN
Avances en Energías Renovables y Medio Ambiente; vol. 21
Neste trabalho realizou-se um estudo com três modelos de estimativa para realizar a estimativa da irradiação global incidente em uma superfície com inclinação de 22,85° (IG&lt;sub&gt;β&lt;/sub&gt;), a partir dos dados da irradiação solar gobal na superfície horizontal (IG&lt;sub&gt;H&lt;/sub&gt;) medidos na partição horária no  período de abril de 1998 a agosto de 2001 na estação climatológica da Faculdade de Ciências  Agronômicas da UNESP no câmpus de Butucatu/SP/Brasil, sendo eles: o modelo estatístico (ME) (Liu &amp; Jordan, 1963) e os modelos de redes neurais artificiais (RNA), Perceptron Multicamadas ( MultLayer Perceptron  - MLP) utilizando algoritmo  Backpropagation  e Rede de Regressão Generalizada ( Generalized Regression Neural Network -  GRNN). O modelo clássico obtido por regressão e os modelos de rede treinados, foram validados em duas bases de dados classificadas como anos típicos (AT) e anos atípicos (AAT). Para o treinamento das redes, foram realizadas 8 combinações de variáveis astronômicas e geográficas, medidas e calculadas. Os índices estatísticos de avaliação de desempenho utilizados (r e RMSE%) obtidos no modelo clássico foram: r&lt;sub&gt;AT&lt;/sub&gt;=0,9927, RMSE%&lt;sub&gt;AT&lt;/sub&gt;=6,5898 e r&lt;sub&gt;AAT&lt;/sub&gt;=0,9960, RMSE%&lt;sub&gt;AAT&lt;/sub&gt;=4,8062, os índices obtidos com a melhor combinação (RNA3) para a rede MLP foram: r&lt;sub&gt;AT&lt;/sub&gt;=0,9941, RMSE%&lt;sub&gt;AT&lt;/sub&gt;=5,9849 e r&lt;sub&gt;AAT&lt;/sub&gt;=0,9984, RMSE%&lt;sub&gt;AAT&lt;/sub&gt;=3,0561, e os índices obtidos com a melhor combinação (RNA3) para a rede GRNN foram: r&lt;sub&gt;AT&lt;/sub&gt;=0,9975, RMSE%&lt;sub&gt;AT&lt;/sub&gt;=3,8808 e r&lt;sub&gt;AAT&lt;/sub&gt;=0,9989, RMSE%&lt;sub&gt;AAT&lt;/sub&gt;=2,6050. Os resultados mostram que os três modelos apresentaram bons resultados nas estimativas da IG&lt;sub&gt;β&lt;/sub&gt; a partir dos dados medidos da IG&lt;sub&gt;H&lt;/sub&gt;, porém entre os modelos de RNA, destaca-se os resultados obtidos pela GRNN na estimativa da IG&lt;sub&gt;β&lt;/sub&gt;.; In this work, a study was carried out with three estimation models to estimate the global irradiance incident on a slope surface of 22.85 ° (IG&lt;sub&gt;β&lt;/sub&gt;), from the data of the gobal solar irradiation on the horizontal surface (IGH&lt;sub&gt;H&lt;/sub&gt;) measured in the hourly partition from April 1998 to August 2001 at the climatological station of the Faculty of Agronomic Sciences of UNESP in the Butucatu / SP / Brazil campus, being them: the statistical model (ME) (Liu &amp; Jordan, 1963) and the artificial neural network (ANN) models, Perceptron Multicamadas (MultLayer Perceptron - MLP) using Backpropagation and Generalized Regression Neural Network (GRNN) algorithms. The classical regression model and the trained network models were validated in two databases classified as typical years (AT) and atypical years (AAT). For training of the networks, training sessions were carried out with 8 combinations of astronomical and geographic variables, measured and calculated. The statistical performance evaluation indices (rMSE%) obtained in the classic model were: r&lt;sub&gt;AT&lt;/sub&gt; = 0.9927, RMSE% &lt;sub&gt;AT&lt;/sub&gt; = 6.5898 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.9960, RMSE% &lt;sub&gt;AAT&lt;/sub&gt; = 4.8062, the indices obtained with the best combination (RNA3) for the MLP network were: r&lt;sub&gt;AT&lt;/sub&gt; = 0.9941, RMSE% &lt;sub&gt;AT&lt;/sub&gt; = 5.9849 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.9984, RMSE% &lt;sub&gt;AAT&lt;/sub&gt; = 3.0561, and the indices obtained with the best combination RNA3) for the GRNN network were: r&lt;sub&gt;AT&lt;/sub&gt; = 0.9975, RMSE% &lt;sub&gt;AT&lt;/sub&gt; = 3.8080 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.9989, RMSE% &lt;sub&gt;AAT&lt;/sub&gt; = 2.6050. The results show that the three models presented good results in the IG&lt;sub&gt;β&lt;/sub&gt; estimates from the measured data of the IG&lt;sub&gt;H&lt;/sub&gt;, but among the RNA models, the results obtained by the GRNN in the IG&lt;sub&gt;β&lt;/sub&gt; estimation stand out.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140839</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>Neste trabalho realizou-se um estudo com três modelos de estimativa para realizar a estimativa da irradiação global incidente em uma superfície com inclinação de 22,85° (IG&lt;sub&gt;β&lt;/sub&gt;), a partir dos dados da irradiação solar gobal na superfície horizontal (IG&lt;sub&gt;H&lt;/sub&gt;) medidos na partição horária no  período de abril de 1998 a agosto de 2001 na estação climatológica da Faculdade de Ciências  Agronômicas da UNESP no câmpus de Butucatu/SP/Brasil, sendo eles: o modelo estatístico (ME) (Liu &amp; Jordan, 1963) e os modelos de redes neurais artificiais (RNA), Perceptron Multicamadas ( MultLayer Perceptron  - MLP) utilizando algoritmo  Backpropagation  e Rede de Regressão Generalizada ( Generalized Regression Neural Network -  GRNN). O modelo clássico obtido por regressão e os modelos de rede treinados, foram validados em duas bases de dados classificadas como anos típicos (AT) e anos atípicos (AAT). Para o treinamento das redes, foram realizadas 8 combinações de variáveis astronômicas e geográficas, medidas e calculadas. Os índices estatísticos de avaliação de desempenho utilizados (r e RMSE%) obtidos no modelo clássico foram: r&lt;sub&gt;AT&lt;/sub&gt;=0,9927, RMSE%&lt;sub&gt;AT&lt;/sub&gt;=6,5898 e r&lt;sub&gt;AAT&lt;/sub&gt;=0,9960, RMSE%&lt;sub&gt;AAT&lt;/sub&gt;=4,8062, os índices obtidos com a melhor combinação (RNA3) para a rede MLP foram: r&lt;sub&gt;AT&lt;/sub&gt;=0,9941, RMSE%&lt;sub&gt;AT&lt;/sub&gt;=5,9849 e r&lt;sub&gt;AAT&lt;/sub&gt;=0,9984, RMSE%&lt;sub&gt;AAT&lt;/sub&gt;=3,0561, e os índices obtidos com a melhor combinação (RNA3) para a rede GRNN foram: r&lt;sub&gt;AT&lt;/sub&gt;=0,9975, RMSE%&lt;sub&gt;AT&lt;/sub&gt;=3,8808 e r&lt;sub&gt;AAT&lt;/sub&gt;=0,9989, RMSE%&lt;sub&gt;AAT&lt;/sub&gt;=2,6050. Os resultados mostram que os três modelos apresentaram bons resultados nas estimativas da IG&lt;sub&gt;β&lt;/sub&gt; a partir dos dados medidos da IG&lt;sub&gt;H&lt;/sub&gt;, porém entre os modelos de RNA, destaca-se os resultados obtidos pela GRNN na estimativa da IG&lt;sub&gt;β&lt;/sub&gt;.

In this work, a study was carried out with three estimation models to estimate the global irradiance incident on a slope surface of 22.85 ° (IG&lt;sub&gt;β&lt;/sub&gt;), from the data of the gobal solar irradiation on the horizontal surface (IGH&lt;sub&gt;H&lt;/sub&gt;) measured in the hourly partition from April 1998 to August 2001 at the climatological station of the Faculty of Agronomic Sciences of UNESP in the Butucatu / SP / Brazil campus, being them: the statistical model (ME) (Liu &amp; Jordan, 1963) and the artificial neural network (ANN) models, Perceptron Multicamadas (MultLayer Perceptron - MLP) using Backpropagation and Generalized Regression Neural Network (GRNN) algorithms. The classical regression model and the trained network models were validated in two databases classified as typical years (AT) and atypical years (AAT). For training of the networks, training sessions were carried out with 8 combinations of astronomical and geographic variables, measured and calculated. The statistical performance evaluation indices (rMSE%) obtained in the classic model were: r&lt;sub&gt;AT&lt;/sub&gt; = 0.9927, RMSE% &lt;sub&gt;AT&lt;/sub&gt; = 6.5898 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.9960, RMSE% &lt;sub&gt;AAT&lt;/sub&gt; = 4.8062, the indices obtained with the best combination (RNA3) for the MLP network were: r&lt;sub&gt;AT&lt;/sub&gt; = 0.9941, RMSE% &lt;sub&gt;AT&lt;/sub&gt; = 5.9849 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.9984, RMSE% &lt;sub&gt;AAT&lt;/sub&gt; = 3.0561, and the indices obtained with the best combination RNA3) for the GRNN network were: r&lt;sub&gt;AT&lt;/sub&gt; = 0.9975, RMSE% &lt;sub&gt;AT&lt;/sub&gt; = 3.8080 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.9989, RMSE% &lt;sub&gt;AAT&lt;/sub&gt; = 2.6050. The results show that the three models presented good results in the IG&lt;sub&gt;β&lt;/sub&gt; estimates from the measured data of the IG&lt;sub&gt;H&lt;/sub&gt;, but among the RNA models, the results obtained by the GRNN in the IG&lt;sub&gt;β&lt;/sub&gt; estimation stand out.</dc:description>
</item>
<item>
<title>Previsão em curto prazo de índice de claridade utilizando redes neurais e variáveis sazonais</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140831</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
Este trabajo busca contribuir a la predicción de la radiación solar horaria en horizontes de hasta 12 horas adelante. Para ello, han sido empleadas Redes Neuronales (ANNs) del tipo Perceptron Multicapa. A su vez, dichas redes han empleado, como variables regresoras, datos horarios de Índice de Claridad (Kt) y variables determinísticas estacionales con el propósito de mejorar la comprensión en cuanto a las características de estacionalidad diaria y anual de la serie de Kt para un emplazamiento en Petrolina-PE-Brasil. El objetivo es comparar los resultados logrados con el empleo de dichas variables estacionales (que, entre otros aspectos, tienen características de variables difusas - fuzzy variables) con aquellos logrados por otros modelos reportados por diferentes autores como las mismas ANNs sin las variables estacionales, los Modelos Autoregresivos y la Persistencia. El error (nRMSD) del modelo final ha variado entre 17,8% y 25,7% para horizontes de predicción desde 1 hasta 12 horas adelante. Las ANNs han superado el desempeño de la Persistencia y del Modelo Autoregresivo. Se ha demostrado que el empleo de las variables estacionales ha mejorado las predicciones de Kt realizadas por las ANNs.; This work aims to improve solar radiation forecast for horizons up to 12 hours ahead. In this sense, Neural Networks (ANN) of Multilayer Perceptron type were proposed, using as regressive variables, hourly clearness index (Kt) and seasonal deterministic variables, with the purpose of enhancing the understanding on the characteristics of daily and annual seasonal of Kt series for the city of Petrolina-PE-Brazil. The objective is to compare the results obtained with the use of such seasonal variables (which, among other aspects, have characteristics of fuzzy variables) with results of other models reported in the literature, such as ANNs without the use of seasonal variables, the Auto-Regressive Model and Persistence. The error (nRMSD) associated with the final model differs from 17.8% to 25.7% for horizons from 1 to 12 hours ahead. Neural networks surpassed the Persistence and the Autoregressive Model. It was proved that the use of the seasonal variables improved the results of Kt predictions using ANNs.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140831</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>Este trabajo busca contribuir a la predicción de la radiación solar horaria en horizontes de hasta 12 horas adelante. Para ello, han sido empleadas Redes Neuronales (ANNs) del tipo Perceptron Multicapa. A su vez, dichas redes han empleado, como variables regresoras, datos horarios de Índice de Claridad (Kt) y variables determinísticas estacionales con el propósito de mejorar la comprensión en cuanto a las características de estacionalidad diaria y anual de la serie de Kt para un emplazamiento en Petrolina-PE-Brasil. El objetivo es comparar los resultados logrados con el empleo de dichas variables estacionales (que, entre otros aspectos, tienen características de variables difusas - fuzzy variables) con aquellos logrados por otros modelos reportados por diferentes autores como las mismas ANNs sin las variables estacionales, los Modelos Autoregresivos y la Persistencia. El error (nRMSD) del modelo final ha variado entre 17,8% y 25,7% para horizontes de predicción desde 1 hasta 12 horas adelante. Las ANNs han superado el desempeño de la Persistencia y del Modelo Autoregresivo. Se ha demostrado que el empleo de las variables estacionales ha mejorado las predicciones de Kt realizadas por las ANNs.

This work aims to improve solar radiation forecast for horizons up to 12 hours ahead. In this sense, Neural Networks (ANN) of Multilayer Perceptron type were proposed, using as regressive variables, hourly clearness index (Kt) and seasonal deterministic variables, with the purpose of enhancing the understanding on the characteristics of daily and annual seasonal of Kt series for the city of Petrolina-PE-Brazil. The objective is to compare the results obtained with the use of such seasonal variables (which, among other aspects, have characteristics of fuzzy variables) with results of other models reported in the literature, such as ANNs without the use of seasonal variables, the Auto-Regressive Model and Persistence. The error (nRMSD) associated with the final model differs from 17.8% to 25.7% for horizons from 1 to 12 hours ahead. Neural networks surpassed the Persistence and the Autoregressive Model. It was proved that the use of the seasonal variables improved the results of Kt predictions using ANNs.</dc:description>
</item>
<item>
<title>Estimativa da fração transmitida da irradiação difusa horária por meio de modelo estátistico e rede neural do tipo regressão generalizada (GRNN)</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140806</link>
<description>Articulo
Estimation of the transmitted fraction of hourly diffuse irradiation by means of statistical model and generalized regression neural network (GRNN)
Avances en Energías Renovables y Medio Ambiente; vol. 21
É proposto no trabalho dois modelos de estimativas para fração transmitida da irradiação difusa (K&lt;sub&gt;d&lt;/sub&gt;) em função da transmissividade da irradiação global (K&lt;sub&gt;t&lt;/sub&gt;) na partição horária: estatístico e a técnica de Redes Neurais Artificias do tipo Regressão Generalizada (GRNN). O primeiro, usando somente K&lt;sub&gt;t&lt;/sub&gt; como referência e o segundo, uma combinação de seis variáveis astronômicas e meteorológicas. A base dos dados, medida no período de 2000 a 2006, foi utilizada para a obtenção da equação estatística e no treinamento da rede GRNN nas combinações propostas. Na validação dos modelos, foram utilizadas duas bases de dados da irradiação solar difusa, denominadas de anos típico (AT) e atípico (AAT), ambas obtidas a partir da base de dados total de anos. A equação de estimativa foi obtida por regressão polinomial de 4° ordem com coeficiente de correlação r = 0,90. Na comparação entre a estimativa e a medida do modelo estatístico, obteve-se os indicativos estatísticos das duas condições de validação: r&lt;sub&gt;AT&lt;/sub&gt;=0.90 e r&lt;sub&gt;AAT&lt;/sub&gt;=0.89 ; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 30.55% e rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 27.97%, respectivamente. O desempenho da rede GRNN foi melhor nas combinações 2 a 6 em função da entrada de cada variável astronômica e meteorológica, obtendo-se os indicativos estatísticos r&lt;sub&gt;AT&lt;/sub&gt;=0.92 e r&lt;sub&gt;AAT&lt;/sub&gt;=0.91; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 28.04% e rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 26.00% para combinação 2, até os valores de r&lt;sub&gt;AT&lt;/sub&gt;=0.99 e r&lt;sub&gt;AAT&lt;/sub&gt;=0.99; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 7.85% e rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 8.21% para combinação 6, nas duas condições de validação, respectivamente. A comparação dos indicativos estatísticos mostram que a rede GRNN a partir da combinação 2 que tem K&lt;sub&gt;t&lt;/sub&gt; e a irradiação de topo (H₀) como entrada, possui melhor desempenho que o modelo estatistico em estimar K&lt;sub&gt;d&lt;/sub&gt;.; Two models of estimates for diffused radiation fraction (K&lt;sub&gt;d&lt;/sub&gt;) as a function of the transmissivity of global radiation (K&lt;sub&gt;t&lt;/sub&gt;) in the hourly partition: statistical and the technique of Artificial Neural Networks of the Generalized Regression type (GRNN) are proposed. The first, using only K&lt;sub&gt;t&lt;/sub&gt; as a reference and the second, a combination of six astronomical and meteorological variables. The data base, measured between 2000 and 2006, was used to obtain the statistical equation and GRNN training in the proposed combinations. In the validation of the models, two diffuse solar irradiation databases, called typical (AT) and atypical (AAT) years, were used, both obtained from the total database of years. The estimation equation was obtained by a 4 th order polynomial regression with a correlation if coefficient r = 0.89. In the comparison between the estimation and the measurement of the statistical model, we obtained the statistical indicatives of the two validation conditions: r&lt;sub&gt;AT&lt;/sub&gt; = 0.90 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.89; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 30.55% and rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 27.97%, respectively. The performance of the GRNN network was better in combinations 2 to 6 as a function of the input of each astronomical and meteorological variable, obtaining the statistical indicatives r&lt;sub&gt;AT&lt;/sub&gt; = 0.92 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.91; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 28.04% and rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 26.00% for combination 2, up to the values of r&lt;sub&gt;AT&lt;/sub&gt; = 0.99 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.99; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 7.85% and rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 8.21% for combination 6, under the two validation conditions, respectively. The comparison of the statistical indicatives shows that the GRNN network from the combination 2 that has K&lt;sub&gt;t&lt;/sub&gt; and the top (H₀) irradiation as input, performs better than the statistical model in estimating K&lt;sub&gt;d&lt;/sub&gt;.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140806</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>É proposto no trabalho dois modelos de estimativas para fração transmitida da irradiação difusa (K&lt;sub&gt;d&lt;/sub&gt;) em função da transmissividade da irradiação global (K&lt;sub&gt;t&lt;/sub&gt;) na partição horária: estatístico e a técnica de Redes Neurais Artificias do tipo Regressão Generalizada (GRNN). O primeiro, usando somente K&lt;sub&gt;t&lt;/sub&gt; como referência e o segundo, uma combinação de seis variáveis astronômicas e meteorológicas. A base dos dados, medida no período de 2000 a 2006, foi utilizada para a obtenção da equação estatística e no treinamento da rede GRNN nas combinações propostas. Na validação dos modelos, foram utilizadas duas bases de dados da irradiação solar difusa, denominadas de anos típico (AT) e atípico (AAT), ambas obtidas a partir da base de dados total de anos. A equação de estimativa foi obtida por regressão polinomial de 4° ordem com coeficiente de correlação r = 0,90. Na comparação entre a estimativa e a medida do modelo estatístico, obteve-se os indicativos estatísticos das duas condições de validação: r&lt;sub&gt;AT&lt;/sub&gt;=0.90 e r&lt;sub&gt;AAT&lt;/sub&gt;=0.89 ; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 30.55% e rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 27.97%, respectivamente. O desempenho da rede GRNN foi melhor nas combinações 2 a 6 em função da entrada de cada variável astronômica e meteorológica, obtendo-se os indicativos estatísticos r&lt;sub&gt;AT&lt;/sub&gt;=0.92 e r&lt;sub&gt;AAT&lt;/sub&gt;=0.91; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 28.04% e rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 26.00% para combinação 2, até os valores de r&lt;sub&gt;AT&lt;/sub&gt;=0.99 e r&lt;sub&gt;AAT&lt;/sub&gt;=0.99; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 7.85% e rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 8.21% para combinação 6, nas duas condições de validação, respectivamente. A comparação dos indicativos estatísticos mostram que a rede GRNN a partir da combinação 2 que tem K&lt;sub&gt;t&lt;/sub&gt; e a irradiação de topo (H₀) como entrada, possui melhor desempenho que o modelo estatistico em estimar K&lt;sub&gt;d&lt;/sub&gt;.

Two models of estimates for diffused radiation fraction (K&lt;sub&gt;d&lt;/sub&gt;) as a function of the transmissivity of global radiation (K&lt;sub&gt;t&lt;/sub&gt;) in the hourly partition: statistical and the technique of Artificial Neural Networks of the Generalized Regression type (GRNN) are proposed. The first, using only K&lt;sub&gt;t&lt;/sub&gt; as a reference and the second, a combination of six astronomical and meteorological variables. The data base, measured between 2000 and 2006, was used to obtain the statistical equation and GRNN training in the proposed combinations. In the validation of the models, two diffuse solar irradiation databases, called typical (AT) and atypical (AAT) years, were used, both obtained from the total database of years. The estimation equation was obtained by a 4 th order polynomial regression with a correlation if coefficient r = 0.89. In the comparison between the estimation and the measurement of the statistical model, we obtained the statistical indicatives of the two validation conditions: r&lt;sub&gt;AT&lt;/sub&gt; = 0.90 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.89; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 30.55% and rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 27.97%, respectively. The performance of the GRNN network was better in combinations 2 to 6 as a function of the input of each astronomical and meteorological variable, obtaining the statistical indicatives r&lt;sub&gt;AT&lt;/sub&gt; = 0.92 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.91; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 28.04% and rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 26.00% for combination 2, up to the values of r&lt;sub&gt;AT&lt;/sub&gt; = 0.99 and r&lt;sub&gt;AAT&lt;/sub&gt; = 0.99; rRMSE&lt;sub&gt;AT&lt;/sub&gt; = 7.85% and rRMSE&lt;sub&gt;AAT&lt;/sub&gt; = 8.21% for combination 6, under the two validation conditions, respectively. The comparison of the statistical indicatives shows that the GRNN network from the combination 2 that has K&lt;sub&gt;t&lt;/sub&gt; and the top (H₀) irradiation as input, performs better than the statistical model in estimating K&lt;sub&gt;d&lt;/sub&gt;.</dc:description>
</item>
<item>
<title>Precipitaciones y vientos en el clima urbano árido del área metropolitana de San Juan</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140805</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
Complementando estudios previos de clima urbano árido, relevantes para su uso como base de datos de diseño bioclimático, se presenta la estadística 2000-2015, de precipitaciones y vientos con registros de la ciudad de San Juan. Se calculan promedios mensuales, estacionales y anuales, de cada año y del período de 16 años. Del análisis estadístico resulta el verano, la estación de mayor concentración de lluvias y mayor velocidad de vientos. La media de precipitación anual es de 70,24mm; el año de máximo valor resulta el 2005 con 128,8mm y el de mínimo valor el 2012, con 11,8mm. La frecuencia de vientos predominantes es del sector sur con 59% de horas al año, siendo las direcciones SE y SSE las de mayor frecuencia, con 23% y 19% respectivamente. Coincidentemente el sector cardinal con mayor velocidad de vientos es el sur, con máximas de 7,4km/h en el SSE, seguido por el SE con 5,80km/h.; Complementing previous studies of arid urban climate, relevant for use as database for bioclimatic design, 2000-2015 statistics of precipitation and winds with records of the city of San Juan is presented. Monthly, seasonal and annual, averages for each year and for the 16 years are calculated. From the statistical analysis summer, is the period of highest concentration of rainfall and higher wind speed. The average annual precipitation is 70,25mm; the year of maximum value is 2005 with 128,8mm and the minimum value on 2012, with 12,0mm. Prevailing winds frequency is for the southern sector with 59% of hours per year, being the direction SE and SSE of more frequency, with 23% and 19% respectively. Coincidentally the cardinal sector with higher speed winds is the South, with a maximum of 6,75km/h from the SSE, followed by the O with 6,03km/h.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140805</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>Complementando estudios previos de clima urbano árido, relevantes para su uso como base de datos de diseño bioclimático, se presenta la estadística 2000-2015, de precipitaciones y vientos con registros de la ciudad de San Juan. Se calculan promedios mensuales, estacionales y anuales, de cada año y del período de 16 años. Del análisis estadístico resulta el verano, la estación de mayor concentración de lluvias y mayor velocidad de vientos. La media de precipitación anual es de 70,24mm; el año de máximo valor resulta el 2005 con 128,8mm y el de mínimo valor el 2012, con 11,8mm. La frecuencia de vientos predominantes es del sector sur con 59% de horas al año, siendo las direcciones SE y SSE las de mayor frecuencia, con 23% y 19% respectivamente. Coincidentemente el sector cardinal con mayor velocidad de vientos es el sur, con máximas de 7,4km/h en el SSE, seguido por el SE con 5,80km/h.

Complementing previous studies of arid urban climate, relevant for use as database for bioclimatic design, 2000-2015 statistics of precipitation and winds with records of the city of San Juan is presented. Monthly, seasonal and annual, averages for each year and for the 16 years are calculated. From the statistical analysis summer, is the period of highest concentration of rainfall and higher wind speed. The average annual precipitation is 70,25mm; the year of maximum value is 2005 with 128,8mm and the minimum value on 2012, with 12,0mm. Prevailing winds frequency is for the southern sector with 59% of hours per year, being the direction SE and SSE of more frequency, with 23% and 19% respectively. Coincidentally the cardinal sector with higher speed winds is the South, with a maximum of 6,75km/h from the SSE, followed by the O with 6,03km/h.</dc:description>
</item>
<item>
<title>Diseño del año meteorológico típico para la ciudad de Salta capital</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140799</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
Se desarrolló un año meteorológico típico (TMY, del inglés Typical Meteorological Year) con un nuevo método que combina los factores de ponderación de cuatro conjuntos de diferentes generadores de TMY. La definición del TMY es fundamental para la elaboración del archivo climático utilizado por los códigos de Simulación Energética de Edificios. Este trabajo está dedicado a la definición del TMY en la ciudad de Salta (1232 msnm), para ser aplicado en el diseño de viviendas de interés social y colectores solares calentadores de aire. Se partió de datos proporcionados por el Servicio Meteorológico Nacional (SMN) de Argentina sobre diversas variables meteorológicas registradas en intervalos horarios a lo largo de 11 años (2006-2016) en el Aeropuerto Martin M. de Güemes, mientras los datos de radiación fueron proporcionados por el Instituto de Investigaciones de Energía No Convencional (INENCO). En base a criterios estadísticos, para cada mes del año, uno de todos los meses de muestra se cataloga como Mes Meteorológico Típico TMM. La concatenación de los doce TMM define el TMY.; The definition of the typical meteorological year (TMY) is fundamental for the development of the climatic file used by the Building Energy Simulation codes. The TMY generation was performed with four different sets of weighting factors. This work is dedicated to the definition of TMY in the city of Salta (1232 msnm), to be applied in the design of social housing. It was based on data provided by the National Meteorological Service (SMN) of Argentina on various meteorological variables recorded in time intervals over 11 years (2006-2016) at the Martin M. de Güemes Airport, while the radiation data were provided By the Institute of Investigations of Non-Conventional Energy (INENCO). Based on statistical criteria, for each month of the year, one of all sample months is cataloged as TMM Typical Meteorological Month. The concatenation of the twelve TMMs defines the TMY.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140799</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>Se desarrolló un año meteorológico típico (TMY, del inglés Typical Meteorological Year) con un nuevo método que combina los factores de ponderación de cuatro conjuntos de diferentes generadores de TMY. La definición del TMY es fundamental para la elaboración del archivo climático utilizado por los códigos de Simulación Energética de Edificios. Este trabajo está dedicado a la definición del TMY en la ciudad de Salta (1232 msnm), para ser aplicado en el diseño de viviendas de interés social y colectores solares calentadores de aire. Se partió de datos proporcionados por el Servicio Meteorológico Nacional (SMN) de Argentina sobre diversas variables meteorológicas registradas en intervalos horarios a lo largo de 11 años (2006-2016) en el Aeropuerto Martin M. de Güemes, mientras los datos de radiación fueron proporcionados por el Instituto de Investigaciones de Energía No Convencional (INENCO). En base a criterios estadísticos, para cada mes del año, uno de todos los meses de muestra se cataloga como Mes Meteorológico Típico TMM. La concatenación de los doce TMM define el TMY.

The definition of the typical meteorological year (TMY) is fundamental for the development of the climatic file used by the Building Energy Simulation codes. The TMY generation was performed with four different sets of weighting factors. This work is dedicated to the definition of TMY in the city of Salta (1232 msnm), to be applied in the design of social housing. It was based on data provided by the National Meteorological Service (SMN) of Argentina on various meteorological variables recorded in time intervals over 11 years (2006-2016) at the Martin M. de Güemes Airport, while the radiation data were provided By the Institute of Investigations of Non-Conventional Energy (INENCO). Based on statistical criteria, for each month of the year, one of all sample months is cataloged as TMM Typical Meteorological Month. The concatenation of the twelve TMMs defines the TMY.</dc:description>
</item>
<item>
<title>Cubiertas verdes y jardines verticales: Comportamiento térmico y acústico de sistemas modulares</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140749</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
Los problemas ambientales afectan cada vez más a las ciudades contemporáneas. Los efectos del cambio climático producen condiciones adversas en el hábitat y en la calidad de vida. Por lo tanto el desarrollo urbano debe acompañarse de estrategias de diseño para resolver los problemas ambientales y mitigar los efectos producto del calentamiento global. La incorporación de superficies vegetadas en edificios resulta desde varios puntos de vista positiva para satisfacer parte de estos problemas. Se presentan en este trabajo dos estudios en curso sobre sistemas de vegetación aplicadas a envolventes edilicias: una terraza verde en la que se evalúa su comportamiento térmico a partir del registro anual de temperaturas y un jardín vertical que se somete a estudios de absorción sonora de los componentes del sistema en una cámara normalizada. Los resultados demuestran la eficiencia de ambos sistemas: aislación térmica (caso de la cubierta) y aislación sonora (caso del jardín vertical).; Environmental problems affect increasingly contemporary cities. The effects of climate change produce adverse conditions in the habitat and the quality of life. Urban development must therefore carry design strategies to solve environmental problems and mitigate the effects of global warming. The use of green surfaces in buildings is positive from several points of view to solve part of these problems. This paper presents two ongoing studies on vegetation systems applied to building envelopes: a green terrace which evaluates thermal behavior from the annual record of temperatures and a vertical garden that is subjected to studies of sound absorption of the components of the system in a standardized camera. The results show the efficiency of both systems: thermal insulation (green roof´s case) and sound insulation (the vertical garden´s case).
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140749</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>Los problemas ambientales afectan cada vez más a las ciudades contemporáneas. Los efectos del cambio climático producen condiciones adversas en el hábitat y en la calidad de vida. Por lo tanto el desarrollo urbano debe acompañarse de estrategias de diseño para resolver los problemas ambientales y mitigar los efectos producto del calentamiento global. La incorporación de superficies vegetadas en edificios resulta desde varios puntos de vista positiva para satisfacer parte de estos problemas. Se presentan en este trabajo dos estudios en curso sobre sistemas de vegetación aplicadas a envolventes edilicias: una terraza verde en la que se evalúa su comportamiento térmico a partir del registro anual de temperaturas y un jardín vertical que se somete a estudios de absorción sonora de los componentes del sistema en una cámara normalizada. Los resultados demuestran la eficiencia de ambos sistemas: aislación térmica (caso de la cubierta) y aislación sonora (caso del jardín vertical).

Environmental problems affect increasingly contemporary cities. The effects of climate change produce adverse conditions in the habitat and the quality of life. Urban development must therefore carry design strategies to solve environmental problems and mitigate the effects of global warming. The use of green surfaces in buildings is positive from several points of view to solve part of these problems. This paper presents two ongoing studies on vegetation systems applied to building envelopes: a green terrace which evaluates thermal behavior from the annual record of temperatures and a vertical garden that is subjected to studies of sound absorption of the components of the system in a standardized camera. The results show the efficiency of both systems: thermal insulation (green roof´s case) and sound insulation (the vertical garden´s case).</dc:description>
</item>
<item>
<title>Estudio experimental de un dispositivo para mejorar el rendimiento de paneles FV en sistemas de bombeo de agua</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140743</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
El trabajo presenta el diseño y estudio experimental de un sistema para aumentar la eficiencia de paneles fotovoltaicos, mediante enfriamiento con agua, aplicable a sistemas de bombeo. Se construyó un prototipo y se lo ensayó midiendo las variables de operación: Temperaturas representativas, caudal, radiación solar y la respuesta del panel en tensión y corriente. Se presentan los resultados en forma gráfica, mostrando que el sistema alcanza un aumento en la eficiencia de hasta 20 % en el período estudiado. Se concluye que la operación del equipo no ofrece dificultades y que es aplicable para bombeo de agua, especialmente en zonas de clima cálido.; The paper presents the design and experimental study of a system to increase the efficiency of photovoltaic panels, by cooling with water, applicable to pumping systems. A prototype was constructed and tested by measuring the operating variables: Representative temperatures, flow, solar radiation and panel response in voltage and current. Results are presented graphically, showing that the system reaches an increase in efficiency of up to 20% in winter. It is concluded that the operation of the equipment offers no difficulties and that it is applicable for pumping water, especially in warm climate zones
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140743</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>El trabajo presenta el diseño y estudio experimental de un sistema para aumentar la eficiencia de paneles fotovoltaicos, mediante enfriamiento con agua, aplicable a sistemas de bombeo. Se construyó un prototipo y se lo ensayó midiendo las variables de operación: Temperaturas representativas, caudal, radiación solar y la respuesta del panel en tensión y corriente. Se presentan los resultados en forma gráfica, mostrando que el sistema alcanza un aumento en la eficiencia de hasta 20 % en el período estudiado. Se concluye que la operación del equipo no ofrece dificultades y que es aplicable para bombeo de agua, especialmente en zonas de clima cálido.

The paper presents the design and experimental study of a system to increase the efficiency of photovoltaic panels, by cooling with water, applicable to pumping systems. A prototype was constructed and tested by measuring the operating variables: Representative temperatures, flow, solar radiation and panel response in voltage and current. Results are presented graphically, showing that the system reaches an increase in efficiency of up to 20% in winter. It is concluded that the operation of the equipment offers no difficulties and that it is applicable for pumping water, especially in warm climate zones</dc:description>
</item>
<item>
<title>Modelo analítico para estimar el consumo energético para climatización de viviendas en régimen dinámico: Parte 1: análisis del flujo de energía a través de muros</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140740</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
La necesidad de elaborar un procedimiento a nivel nacional de etiquetado de eficiencia energética de inmuebles invita a validar modelos de cálculo de requerimientos de energía para climatización. Los modelos estacionarios no contemplan las variaciones horarias de temperatura y radiación, los modelos de simulación dinámica si bien las contemplan, requieren de recursos y mucha formación por parte de los profesionales. Se propone un modelo que contempla los efectos dinámicos, basado en la linealización del intercambio por radiación y la aproximación de las variables temperatura ambiente y radiación solar con una serie de Fourier hasta el quinto armónico, lo que permite obtener soluciones analíticas. Se presenta el estudio del comportamiento de un muro con el modelo propuesto y se comparan estos resultados con una simulación mediante elementos finitos con el software COMSOL Multiphysics, como validación de la metodología propuesta, obteniendo una diferencia del orden del 5% en promedio en sus efectos sobre la cara interna del muro.; The need for developing a national procedure for building energy efficiency labelling gives an opportunity to validate models used to calculate the energy requirements for climatization. Stationary models do not take into account the hourly variation of temperature and solar radiation; dynamic models, although include this variation, demand computer resources and professional background. In this work, a model, which includes dynamic effects is presented. It is based on the linearization of the radiant heat exchange and on the approximation of ambient temperature and solar radiation by a Fourier series truncated to the fifth harmonic which allows to obtain an analytical solution. To validate the proposed method, the heat flux through a wall was calculated and the results were compared with those obtained with COMSOL Multiphysics by finite element analysis. Different configurations were analyzed and difference of 5% on average was obtained for the effects on the inner surface of the wall.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140740</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>La necesidad de elaborar un procedimiento a nivel nacional de etiquetado de eficiencia energética de inmuebles invita a validar modelos de cálculo de requerimientos de energía para climatización. Los modelos estacionarios no contemplan las variaciones horarias de temperatura y radiación, los modelos de simulación dinámica si bien las contemplan, requieren de recursos y mucha formación por parte de los profesionales. Se propone un modelo que contempla los efectos dinámicos, basado en la linealización del intercambio por radiación y la aproximación de las variables temperatura ambiente y radiación solar con una serie de Fourier hasta el quinto armónico, lo que permite obtener soluciones analíticas. Se presenta el estudio del comportamiento de un muro con el modelo propuesto y se comparan estos resultados con una simulación mediante elementos finitos con el software COMSOL Multiphysics, como validación de la metodología propuesta, obteniendo una diferencia del orden del 5% en promedio en sus efectos sobre la cara interna del muro.

The need for developing a national procedure for building energy efficiency labelling gives an opportunity to validate models used to calculate the energy requirements for climatization. Stationary models do not take into account the hourly variation of temperature and solar radiation; dynamic models, although include this variation, demand computer resources and professional background. In this work, a model, which includes dynamic effects is presented. It is based on the linearization of the radiant heat exchange and on the approximation of ambient temperature and solar radiation by a Fourier series truncated to the fifth harmonic which allows to obtain an analytical solution. To validate the proposed method, the heat flux through a wall was calculated and the results were compared with those obtained with COMSOL Multiphysics by finite element analysis. Different configurations were analyzed and difference of 5% on average was obtained for the effects on the inner surface of the wall.</dc:description>
</item>
<item>
<title>Estimación de producción de energía eléctrica por una central solar de concentración de 1 MWe: Caso de estudio: provincia de Salta (Argentina)</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/140735</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 21
En este trabajo se estima la producción de energía eléctrica utilizando un modelo analítico de una central solar térmica de concentración cilindro-parabólica de foco lineal, de 1 MWe de potencia nominal. Los datos de irradiancia solar directa normal al haz, en frecuencia horaria, para Salta Ciudad y San Carlos (Provincia de Salta), fueron extraídos de la base de datos satelital CM SAF abarcando el periodo de 2000-2005, generando un año típico para cada sitio. Los valores de energía obtenidos, en ambos sitios, están relacionados con la disponibilidad de energía solar en cada sitio.; In this work, the production of electric energy is estimated using an analytical model of a solar thermal power plant with a linear-focussed cylinder-parabolic concentration system and 1MWe nominal power. Normal direct solar irradiance data at hourly frequency for Salta City and San Carlos (Province of Salta) were extracted from the satellite data base CM SAF covering the period 2000-2005, generating a typical year for each site. The electric energy amounts obtained at both sites are related to the availability of solar energy at each site.
</description>
<pubDate>Sun, 01 Jan 2017 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/140735</guid>
<dc:date>2017-01-01T00:00:00Z</dc:date>
<dc:description>En este trabajo se estima la producción de energía eléctrica utilizando un modelo analítico de una central solar térmica de concentración cilindro-parabólica de foco lineal, de 1 MWe de potencia nominal. Los datos de irradiancia solar directa normal al haz, en frecuencia horaria, para Salta Ciudad y San Carlos (Provincia de Salta), fueron extraídos de la base de datos satelital CM SAF abarcando el periodo de 2000-2005, generando un año típico para cada sitio. Los valores de energía obtenidos, en ambos sitios, están relacionados con la disponibilidad de energía solar en cada sitio.

In this work, the production of electric energy is estimated using an analytical model of a solar thermal power plant with a linear-focussed cylinder-parabolic concentration system and 1MWe nominal power. Normal direct solar irradiance data at hourly frequency for Salta City and San Carlos (Province of Salta) were extracted from the satellite data base CM SAF covering the period 2000-2005, generating a typical year for each site. The electric energy amounts obtained at both sites are related to the availability of solar energy at each site.</dc:description>
</item>
</channel>
</rss>
