<title>Vectores energéticos en la transición energética: energía eléctrica e hidrógeno</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/180024</link>
<description>Capitulo de libro
https://sedici.unlp.edu.ar/handle/10915/179883; Hidrógeno en la UNLP: Del pionero a los proyectos actuales
Díaz, Francisco Javier
El hidrógeno verde se posiciona como una de las alternativas más prometedoras para la transición energética, debido a su capacidad para reducir las emisiones de carbono y su potencial como vector energético sostenible. Su producción, a partir de la electrólisis del agua utilizando energía renovable, lo distingue de otras formas de hidrógeno con mayores impactos ambientales. En este artículo resume la relación entre el hidrógeno y los sistemas eléctricos, con especial énfasis en las particularidades del sistema eléctrico argentino. Además se analizan las ventajas, desafíos y perspectivas del hidrógeno verde en el contexto global, destacando su papel en sectores clave como el transporte, la industria y el almacenamiento de energía. Asimismo, se abordan las barreras tecnológicas, económicas y regulatorias que deben superarse para su adopción masiva, junto con las estrategias y políticas necesarias para su desarrollo a gran escala.; Green hydrogen is positioned as one of the most promising alternatives for the energy transition, due to its ability to reduce carbon emissions and its potential as a sustainable energy carrier. Its production, through water electrolysis using renewable energy, sets it apart from other forms of hydrogen with higher environmental impacts. This article summarizes the relationship between hydrogen and electrical systems, with a particular focus on the specifi cs of the Argentine electrical system. It also analyzes the advantages, challenges, and prospects of green hydrogen in the global context, highlighting its role in key sectors such as transportation, industry, and energy storage. Furthermore, it addresses the technological, economic, and regulatory barriers that must be overcome for its widespread adoption, along with the strategies and policies necessary for its large-scale development.
Universidad Nacional de La Plata (UNLP)
</description>
<pubDate>Wed, 01 Jan 2025 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/180024</guid>
<dc:date>2025-01-01T00:00:00Z</dc:date>
<dc:description>El hidrógeno verde se posiciona como una de las alternativas más prometedoras para la transición energética, debido a su capacidad para reducir las emisiones de carbono y su potencial como vector energético sostenible. Su producción, a partir de la electrólisis del agua utilizando energía renovable, lo distingue de otras formas de hidrógeno con mayores impactos ambientales. En este artículo resume la relación entre el hidrógeno y los sistemas eléctricos, con especial énfasis en las particularidades del sistema eléctrico argentino. Además se analizan las ventajas, desafíos y perspectivas del hidrógeno verde en el contexto global, destacando su papel en sectores clave como el transporte, la industria y el almacenamiento de energía. Asimismo, se abordan las barreras tecnológicas, económicas y regulatorias que deben superarse para su adopción masiva, junto con las estrategias y políticas necesarias para su desarrollo a gran escala.

Green hydrogen is positioned as one of the most promising alternatives for the energy transition, due to its ability to reduce carbon emissions and its potential as a sustainable energy carrier. Its production, through water electrolysis using renewable energy, sets it apart from other forms of hydrogen with higher environmental impacts. This article summarizes the relationship between hydrogen and electrical systems, with a particular focus on the specifi cs of the Argentine electrical system. It also analyzes the advantages, challenges, and prospects of green hydrogen in the global context, highlighting its role in key sectors such as transportation, industry, and energy storage. Furthermore, it addresses the technological, economic, and regulatory barriers that must be overcome for its widespread adoption, along with the strategies and policies necessary for its large-scale development.</dc:description>
</item>
<item>
<title>An online short-circuit impedance estimation approach to power transformer fault detection</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/167213</link>
<description>Objeto de conferencia
XX Reunión de Trabajo en Procesamiento de la Información y Control (Oberá, Misiones, 1º al 3 de noviembre de 2023); RPIC 2023. Actas de la XX Reunión de Trabajo en Procesamiento de la Información y Control
In addition to offline testing in transformers, advanced diagnostic techniques are experiencing significant advancements in on-line monitoring to ensure the continuity of electrical service and to minimize the costs associated with equipment repair and replacement. This paper presents a strategy for incipient fault detection in power transformers through online measurement of winding impedances. The strategy is based on calculating the series impedance for each phase, which includes the transformer and the connected equipment, by measuring the electrical variables of the transformer. Finally, a single fault indicator is obtained that provides information on the fault severity and the phase affected. The strategy is tested by finite element method simulations for different load conditions and fault severities. The strategy is validated with laboratory results on a 10 kVA three-phase transformer. The results obtained show the effectiveness of the proposed strategy in detecting faults in power transformers.
</description>
<pubDate>Sun, 01 Jan 2023 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/167213</guid>
<dc:date>2023-01-01T00:00:00Z</dc:date>
<dc:description>In addition to offline testing in transformers, advanced diagnostic techniques are experiencing significant advancements in on-line monitoring to ensure the continuity of electrical service and to minimize the costs associated with equipment repair and replacement. This paper presents a strategy for incipient fault detection in power transformers through online measurement of winding impedances. The strategy is based on calculating the series impedance for each phase, which includes the transformer and the connected equipment, by measuring the electrical variables of the transformer. Finally, a single fault indicator is obtained that provides information on the fault severity and the phase affected. The strategy is tested by finite element method simulations for different load conditions and fault severities. The strategy is validated with laboratory results on a 10 kVA three-phase transformer. The results obtained show the effectiveness of the proposed strategy in detecting faults in power transformers.</dc:description>
</item>
<item>
<title>Desconexión de carga: Evaluación de la reaceleración de motores de una planta industrial</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/163061</link>
<description>Objeto de conferencia
VI Congreso Bienal ARGENCON 2022 (San Juan, 7, 8 y 9 de septiembre de 2022)
En este artículo se describe la metodología para analizar el comportamiento de los motores de inducción instalados en una planta industrial ante fallas en la barra principal de la misma. &#13;
El estudio consiste en representar el modelo eléctrico de la planta considerando como elemento fundamental los motores de inducción junto con sus cargas mecánicas. Se valida el modelo a partir de comparar la simulación con una falla ocurrida en la barra principal que provocó el colapso del sistema.&#13;
Se analiza la evolución temporal del sistema considerando el comportamiento de los motores, la actuación de las protecciones de tensión y corriente de la planta.&#13;
Se plantea un sistema de desconexión de carga ante huecos de tensión de duración y profundidad determinados para evitar el colapso de la planta.
</description>
<pubDate>Sat, 01 Jan 2022 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/163061</guid>
<dc:date>2022-01-01T00:00:00Z</dc:date>
<dc:description>En este artículo se describe la metodología para analizar el comportamiento de los motores de inducción instalados en una planta industrial ante fallas en la barra principal de la misma. &#13;
El estudio consiste en representar el modelo eléctrico de la planta considerando como elemento fundamental los motores de inducción junto con sus cargas mecánicas. Se valida el modelo a partir de comparar la simulación con una falla ocurrida en la barra principal que provocó el colapso del sistema.&#13;
Se analiza la evolución temporal del sistema considerando el comportamiento de los motores, la actuación de las protecciones de tensión y corriente de la planta.&#13;
Se plantea un sistema de desconexión de carga ante huecos de tensión de duración y profundidad determinados para evitar el colapso de la planta.</dc:description>
</item>
<item>
<title>Circuitos y sistemas lineales: Elementos de análisis y síntesis</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/162470</link>
<description>Libro
Este libro fue elaborado para la materia Circuitos y Sistemas Lineales que, conforme al Plan de Estudios 2018, corresponde al sexto semestre de las carreras de Ingeniería Electrónica, Ingeniería en Energía Eléctrica e Ingeniería en Telecomunicaciones del Departamento de Electrotecnia de la Facultad de Ingeniería, Universidad Nacional de La Plata. Una característica muy importante de la actualidad académica de la Facultad de Ingeniería, es la concurrencia simultánea de estudiantes originales del plan de estudios del año 2018 y de estudiantes que originalmente se inscribieron en el plan de estudios del año 2002 y que han optado por cambiar al nuevo plan 2018. Para estos últimos, la equivalencia con esta materia es particularmente crítica, debido la redistribución que han sufrido algunos temas entre materias del cuarto, quinto y sexto semestre del Plan 2018. Por otra parte, si bien la lectura de la bibliografía clásica es muy importante en la formación de un ingeniero, al promover el desarrollo de la capacidad de investigación bibliográfica, la comprensión de diferentes enfoques, la interpretación de diferentes notaciones, etc., cuando una materia posee un contenido tan amplio, ciertamente tiene un valor enorme para las/los estudiantes contar con una única fuente que contenga la totalidad del programa; y al presente no existe un único libro que lo abarque con la profundidad adecuada. Esto impuso la necesidad de elaborar un libro en el cual la totalidad del alumnado encuentre todo el material necesario para comprender todos los temas contenidos en el programa de la materia. A tal fin, se crearon Apéndices con algunos temas afectados por la redistribución debida al cambio de plan, y que son requeridos para la correcta comprensión del contenido de la materia, ya sea para nivelar conocimientos, o como referencia para algunos temas puntuales. La premisa fue por un lado, presentar los temas del programa de la materia con los fundamentos teóricos adecuados al nivel de conocimientos de las/los estudiantes y, por otro lado, ejemplificar con todo detalle la aplicación a la resolución de problemas prácticos de cada tema desarrollado.
Edición del autor
</description>
<pubDate>Mon, 01 Jan 2024 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/162470</guid>
<dc:date>2024-01-01T00:00:00Z</dc:date>
<dc:description>Este libro fue elaborado para la materia Circuitos y Sistemas Lineales que, conforme al Plan de Estudios 2018, corresponde al sexto semestre de las carreras de Ingeniería Electrónica, Ingeniería en Energía Eléctrica e Ingeniería en Telecomunicaciones del Departamento de Electrotecnia de la Facultad de Ingeniería, Universidad Nacional de La Plata. Una característica muy importante de la actualidad académica de la Facultad de Ingeniería, es la concurrencia simultánea de estudiantes originales del plan de estudios del año 2018 y de estudiantes que originalmente se inscribieron en el plan de estudios del año 2002 y que han optado por cambiar al nuevo plan 2018. Para estos últimos, la equivalencia con esta materia es particularmente crítica, debido la redistribución que han sufrido algunos temas entre materias del cuarto, quinto y sexto semestre del Plan 2018. Por otra parte, si bien la lectura de la bibliografía clásica es muy importante en la formación de un ingeniero, al promover el desarrollo de la capacidad de investigación bibliográfica, la comprensión de diferentes enfoques, la interpretación de diferentes notaciones, etc., cuando una materia posee un contenido tan amplio, ciertamente tiene un valor enorme para las/los estudiantes contar con una única fuente que contenga la totalidad del programa; y al presente no existe un único libro que lo abarque con la profundidad adecuada. Esto impuso la necesidad de elaborar un libro en el cual la totalidad del alumnado encuentre todo el material necesario para comprender todos los temas contenidos en el programa de la materia. A tal fin, se crearon Apéndices con algunos temas afectados por la redistribución debida al cambio de plan, y que son requeridos para la correcta comprensión del contenido de la materia, ya sea para nivelar conocimientos, o como referencia para algunos temas puntuales. La premisa fue por un lado, presentar los temas del programa de la materia con los fundamentos teóricos adecuados al nivel de conocimientos de las/los estudiantes y, por otro lado, ejemplificar con todo detalle la aplicación a la resolución de problemas prácticos de cada tema desarrollado.</dc:description>
</item>
<item>
<title>Métodos prácticos para la mitigación de perturbaciones en redes de distribución</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/159386</link>
<description>Objeto de conferencia
Congreso Internacional de Distribución Eléctrica (CIDEL) (Buenos Aires, 31 de octubre al 2 de noviembre de 2022)
En Argentina, las Perturbaciones (básicamente armónicas y flicker) se encuentran reguladas. Como consecuencia de ello, en caso de detectarse niveles de éstas por encima de los límites existentes se aplican sanciones a las Distribuidoras.&#13;
El presente Trabajo comienza con una descripción sucinta de las Perturbaciones reguladas (definiciones, causas, efectos y herramientas de mitigación existentes). Luego de ello se exponen, en forma cualitativa, una serie de casos – en su mayoría exitosos – en los que debieron mitigarse dichas Perturbaciones en distintos puntos de la red de Distribución. Las experiencias incluyen resultados de mediciones previas y posteriores a la implementación de la solución propuesta, y una descripción de las acciones llevadas a cabo en cada caso.&#13;
Se trata de cinco casos, dos de ellos referidos al tratamiento de armónicas y los tres restantes, a la mitigación de flicker en redes de distribución.&#13;
Al final del Trabajo se enumeran las conclusiones y las respectivas lecciones aprendidas.&#13;
Cabe señalar que el Trabajo resultará una valiosa fuente de información para aquellos profesionales del sector dedicados al abordaje de Perturbaciones en redes de distribución, en virtud que los métodos empleados en la práctica no suelen estar documentados en la bibliografía existente sobre la temática.
</description>
<pubDate>Sat, 01 Jan 2022 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/159386</guid>
<dc:date>2022-01-01T00:00:00Z</dc:date>
<dc:description>En Argentina, las Perturbaciones (básicamente armónicas y flicker) se encuentran reguladas. Como consecuencia de ello, en caso de detectarse niveles de éstas por encima de los límites existentes se aplican sanciones a las Distribuidoras.&#13;
El presente Trabajo comienza con una descripción sucinta de las Perturbaciones reguladas (definiciones, causas, efectos y herramientas de mitigación existentes). Luego de ello se exponen, en forma cualitativa, una serie de casos – en su mayoría exitosos – en los que debieron mitigarse dichas Perturbaciones en distintos puntos de la red de Distribución. Las experiencias incluyen resultados de mediciones previas y posteriores a la implementación de la solución propuesta, y una descripción de las acciones llevadas a cabo en cada caso.&#13;
Se trata de cinco casos, dos de ellos referidos al tratamiento de armónicas y los tres restantes, a la mitigación de flicker en redes de distribución.&#13;
Al final del Trabajo se enumeran las conclusiones y las respectivas lecciones aprendidas.&#13;
Cabe señalar que el Trabajo resultará una valiosa fuente de información para aquellos profesionales del sector dedicados al abordaje de Perturbaciones en redes de distribución, en virtud que los métodos empleados en la práctica no suelen estar documentados en la bibliografía existente sobre la temática.</dc:description>
</item>
<item>
<title>Experiencias en la incorporación de energía solar fotovoltaica en establecimientos de baja tensión</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/141420</link>
<description>Articulo
Avances en Energías Renovables y Medio Ambiente; vol. 20
A fin de evaluar el efecto que la presencia del generador tiene sobre la red preexistente, se realizaron mediciones de armónicas normalizadas, tanto en la tensión como en la corriente, justamente en bornes de los paneles y los respectivos convertidores. Adicionalmente, se midió la energía generada e inyectada a la red interna, como así también el Nivel de Tensión en la barra.&#13;
En este Trabajo se presenta un análisis completo de las mediciones efectuadas, evaluando el contenido armónico según la hora del día y por lo tanto conforme a la energía generada por los paneles. Se presta particular atención, además, al tipo de día que se trate (laborable o no laborable), dado que esto afecta directamente al consumo global del edificio.&#13;
Finalmente, se concluye si la inclusión del generador fotovoltaico tiene - o no - un impacto directo sobre el establecimiento, en materia de Calidad de Servicio Eléctrico.; In order to assess the effect of the PV-Generator on the preexisting LV network, normalized measurements of harmonic content were performed. Such measurements were performed at the point of coupling between the generator – and the corresponding converters – and the internal LV network. In addition, the energy generated and injected to the LV network as well as the Voltage Magnitude in the internal bar were also measured.&#13;
In the article a complete analysis of the measurement results is presented. The harmonic content is assessed according to the hour of the day, and consequently the energy generated by the PV panels. Added to this, we analyze the harmonic content distinguishing between working days and weekends, since the global consumption of the building depends on the type of day.&#13;
Finally, it is concluded whether the inclusion of the PV generator affects the building, basically in terms of Power Quality.
</description>
<pubDate>Fri, 01 Jan 2016 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/141420</guid>
<dc:date>2016-01-01T00:00:00Z</dc:date>
<dc:description>A fin de evaluar el efecto que la presencia del generador tiene sobre la red preexistente, se realizaron mediciones de armónicas normalizadas, tanto en la tensión como en la corriente, justamente en bornes de los paneles y los respectivos convertidores. Adicionalmente, se midió la energía generada e inyectada a la red interna, como así también el Nivel de Tensión en la barra.&#13;
En este Trabajo se presenta un análisis completo de las mediciones efectuadas, evaluando el contenido armónico según la hora del día y por lo tanto conforme a la energía generada por los paneles. Se presta particular atención, además, al tipo de día que se trate (laborable o no laborable), dado que esto afecta directamente al consumo global del edificio.&#13;
Finalmente, se concluye si la inclusión del generador fotovoltaico tiene - o no - un impacto directo sobre el establecimiento, en materia de Calidad de Servicio Eléctrico.

In order to assess the effect of the PV-Generator on the preexisting LV network, normalized measurements of harmonic content were performed. Such measurements were performed at the point of coupling between the generator – and the corresponding converters – and the internal LV network. In addition, the energy generated and injected to the LV network as well as the Voltage Magnitude in the internal bar were also measured.&#13;
In the article a complete analysis of the measurement results is presented. The harmonic content is assessed according to the hour of the day, and consequently the energy generated by the PV panels. Added to this, we analyze the harmonic content distinguishing between working days and weekends, since the global consumption of the building depends on the type of day.&#13;
Finally, it is concluded whether the inclusion of the PV generator affects the building, basically in terms of Power Quality.</dc:description>
</item>
<item>
<title>Dynamic Speckle Laser Technique for the Characterization of Electrotechnical-porcelain</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/128994</link>
<description>Objeto de conferencia
Progress In Electromagnetics Research Symposium  - PIERS 2015 (Praga, 6 al 9 de julio de 2015); PIERS 2015 Prague Proceedings
This work analyzes the quality of two types of commercial electro-technical-porcelain using textural and physical-chemical methods: BET surface area and pore size by gas adsorption, X-ray powder di®raction; Electronic Microscopy and Energy dispersive X-ray analysis, Infrared Spectroscopy and their water adsorption capacity by the Dynamic Speckle Laser technique.&#13;
Experimental results showed the evolution of the speckle patterns during hydro-adsorption pro- cess, permitting to discriminate di®erent behavior for each material. It was determined that it is possible to correlate changes in the speckle patterns with the porosity and chemical composition of materials.
</description>
<pubDate>Thu, 01 Jan 2015 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/128994</guid>
<dc:date>2015-01-01T00:00:00Z</dc:date>
<dc:description>This work analyzes the quality of two types of commercial electro-technical-porcelain using textural and physical-chemical methods: BET surface area and pore size by gas adsorption, X-ray powder di®raction; Electronic Microscopy and Energy dispersive X-ray analysis, Infrared Spectroscopy and their water adsorption capacity by the Dynamic Speckle Laser technique.&#13;
Experimental results showed the evolution of the speckle patterns during hydro-adsorption pro- cess, permitting to discriminate di®erent behavior for each material. It was determined that it is possible to correlate changes in the speckle patterns with the porosity and chemical composition of materials.</dc:description>
</item>
<item>
<title>Sistema volante para la medición de tensiones en estaciones transformadoras de AT utilizando sensores de campo eléctrico</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/90588</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do CIGRE (ERIAC 2019) (Foz do Iguaçu, Brasil, 19 a 23 de maio de 2019)
En este artículo se analiza la aplicación de Sensores de Campo Eléctrico (SCE), desarrollados por el IITREE-FI-UNLP, para la medición de tensiones en el rango de 5 Hz a 10 MHz. Basándose en mediciones realizadas sobre instalaciones reales, se propone un método para incorporar (de manera complementaria) estos dispositivos en Estaciones Transformadoras de Alta Tensión. De esta manera se podría cubrir parcialmente la carencia, respecto de su respuesta en frecuencia, de los tradicionales transformadores de tensión (TV), utilizados en las Subestaciones y contemplando particularmente la potencial necesidad de obtener mediciones de Calidad de Servicio y transitorios de maniobra.
Trabajo A3-02
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/90588</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>En este artículo se analiza la aplicación de Sensores de Campo Eléctrico (SCE), desarrollados por el IITREE-FI-UNLP, para la medición de tensiones en el rango de 5 Hz a 10 MHz. Basándose en mediciones realizadas sobre instalaciones reales, se propone un método para incorporar (de manera complementaria) estos dispositivos en Estaciones Transformadoras de Alta Tensión. De esta manera se podría cubrir parcialmente la carencia, respecto de su respuesta en frecuencia, de los tradicionales transformadores de tensión (TV), utilizados en las Subestaciones y contemplando particularmente la potencial necesidad de obtener mediciones de Calidad de Servicio y transitorios de maniobra.</dc:description>
</item>
<item>
<title>Ensayo y comparación de métodos de transmisión de sincrofasores sobre redes Ethernet</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/90586</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do CIGRE (ERIAC 2019) (Foz do Iguaçu, Brasil, 19 a 23 de maio de 2019)
Se describen en forma teórica diferentes métodos de transmisión de sincrofasores ya conocidos, los cuales fueron utilizados en transmisiones reales y se presentan los resultados de estas experiencias, empleando PMUs con conexiones cableadas a Internet. Los métodos analizados se encuentran descriptos en la norma IEEE C37.118.2-2011 y son los habitualmente utilizados en aplicaciones de PMUs comerciales y descriptos en la literatura afín. Se realiza una completa descripción de los mismos, analizando las principales características, ventajas y desventajas, teniendo en cuenta los algoritmos de eficiencia en el uso de la red que pueden afectar las transmisiones de las PMUs. En sistemas de potencia de países en desarrollo donde se instalan PMUs, la disponibilidad de enlaces Ethernet dedicados o de fibra óptica utilizables para estas aplicaciones puede resultar muy limitada, por lo que las conexiones a través de internet se convierten en una solución alternativa para el enlace de datos. En el presente trabajo se analiza el desempeño de las PMUs vinculadas a través de internet, en términos de calidad de paquetes de datos y latencia, mediante pruebas diseñadas para tal fin. Se presentan análisis estadísticos a partir de resultados obtenidos de experiencias reales y su comparación con los requerimientos de aplicaciones prácticas.
Trabajo D2-04
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/90586</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Se describen en forma teórica diferentes métodos de transmisión de sincrofasores ya conocidos, los cuales fueron utilizados en transmisiones reales y se presentan los resultados de estas experiencias, empleando PMUs con conexiones cableadas a Internet. Los métodos analizados se encuentran descriptos en la norma IEEE C37.118.2-2011 y son los habitualmente utilizados en aplicaciones de PMUs comerciales y descriptos en la literatura afín. Se realiza una completa descripción de los mismos, analizando las principales características, ventajas y desventajas, teniendo en cuenta los algoritmos de eficiencia en el uso de la red que pueden afectar las transmisiones de las PMUs. En sistemas de potencia de países en desarrollo donde se instalan PMUs, la disponibilidad de enlaces Ethernet dedicados o de fibra óptica utilizables para estas aplicaciones puede resultar muy limitada, por lo que las conexiones a través de internet se convierten en una solución alternativa para el enlace de datos. En el presente trabajo se analiza el desempeño de las PMUs vinculadas a través de internet, en términos de calidad de paquetes de datos y latencia, mediante pruebas diseñadas para tal fin. Se presentan análisis estadísticos a partir de resultados obtenidos de experiencias reales y su comparación con los requerimientos de aplicaciones prácticas.</dc:description>
</item>
<item>
<title>Métodos de estimación de sincrofasores: Análisis, evaluación e implementación en entorno de simulación y en hardware</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/90576</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do CIGRE (ERIAC 2019) (Foz do Iguaçu, Brasil, 19 a 23 de maio de 2019)
Este trabajo presenta una descripción y análisis del desempeño de dos algoritmos de estimación de sincrofasores propuestos en la literatura afín. En una implementación real de los mismos, se efectúa un análisis comparativo del desempeño en términos del error teórico de los métodos de estimación. Ambos algoritmos fueron implementados bajo una arquitectura de hardware de bajo costo propuesta para tal fin, con el objetivo de evidenciar los errores inherentes a los métodos de estimación y los errores debidos a factores externos como ruido, error de cuantización y fluctuación de la frecuencia de muestreo. Para realizar el estudio de los algoritmos, se realizaron pruebas bajo condiciones de estado estacionario y bajo condiciones dinámicas. Dichas pruebas se llevaron a cabo según las condiciones especificadas en la norma IEEE C37.118.1-2011 y el error vectorial total obtenido fue utilizado como parámetro de desempeño. La selección de los métodos analizados se realizó a partir de la naturaleza de los mismos, dado que uno de ellos se basa en un análisis en el dominio de la frecuencia utilizando la Transformada Discreta de Fourier Interpolada, mientras que el restante se basa en un análisis en el dominio del tiempo, implementando conversión de frecuencia y filtros pasa bajos del tipo FIR.
Trabajo C2-02
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/90576</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Este trabajo presenta una descripción y análisis del desempeño de dos algoritmos de estimación de sincrofasores propuestos en la literatura afín. En una implementación real de los mismos, se efectúa un análisis comparativo del desempeño en términos del error teórico de los métodos de estimación. Ambos algoritmos fueron implementados bajo una arquitectura de hardware de bajo costo propuesta para tal fin, con el objetivo de evidenciar los errores inherentes a los métodos de estimación y los errores debidos a factores externos como ruido, error de cuantización y fluctuación de la frecuencia de muestreo. Para realizar el estudio de los algoritmos, se realizaron pruebas bajo condiciones de estado estacionario y bajo condiciones dinámicas. Dichas pruebas se llevaron a cabo según las condiciones especificadas en la norma IEEE C37.118.1-2011 y el error vectorial total obtenido fue utilizado como parámetro de desempeño. La selección de los métodos analizados se realizó a partir de la naturaleza de los mismos, dado que uno de ellos se basa en un análisis en el dominio de la frecuencia utilizando la Transformada Discreta de Fourier Interpolada, mientras que el restante se basa en un análisis en el dominio del tiempo, implementando conversión de frecuencia y filtros pasa bajos del tipo FIR.</dc:description>
</item>
<item>
<title>Synchrophasor Communication over Internet: Performance Analysis of different Methods based on Real Experiences</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/90523</link>
<description>Objeto de conferencia
IEEE Power &amp; Energy Society (PES) General Meeting (GM) 2019 Conference &amp; Exposition (Atlanta, Georgia, USA, August 4-8, 2019)
This paper presents a theoretical description and a practical experience in different synchrophasor communication methods applied in real implementations of PMUs connected over both a wired and a mobile internet link. The analyzed methods are proposed in the IEEE Standard C37.118.2-2011 and are the most used in the literature and real applications including commercial PMUs. A complete description is presented and the main characteristics, advantages and disadvantages, including network efficiency algorithms that can affect PMU link are discussed. As PMUs are being applied on existing power systems in developing countries, where dedicated Ethernet or fiber-optic links are not always available, wired internet connections and GSM/GPRS usually become the only possible solutions. Performance of PMUs over Internet, in terms of data frames quality and latency, is analyzed by means of tests designed for this purpose, and statistical analysis of results from real experiences is presented and compared with real applications requirements.
Paper 19PESGM0341.
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/90523</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>This paper presents a theoretical description and a practical experience in different synchrophasor communication methods applied in real implementations of PMUs connected over both a wired and a mobile internet link. The analyzed methods are proposed in the IEEE Standard C37.118.2-2011 and are the most used in the literature and real applications including commercial PMUs. A complete description is presented and the main characteristics, advantages and disadvantages, including network efficiency algorithms that can affect PMU link are discussed. As PMUs are being applied on existing power systems in developing countries, where dedicated Ethernet or fiber-optic links are not always available, wired internet connections and GSM/GPRS usually become the only possible solutions. Performance of PMUs over Internet, in terms of data frames quality and latency, is analyzed by means of tests designed for this purpose, and statistical analysis of results from real experiences is presented and compared with real applications requirements.</dc:description>
</item>
<item>
<title>Comparison of Synchrophasor Estimation Methods in Simulation Environment and Real Hardware Implementation</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/90518</link>
<description>Objeto de conferencia
IEEE  Power &amp; Energy Society (PES) General Meeting (GM) 2018 Conference &amp; Exposition (Portland, Oregon, USA, August 5-9, 2018)
This paper presents a description and performance comparison of two synchrophasor estimation algorithms proposed in the literature. The theoretical error performance is analyzed and compared with a practical implementation. Both synchrophasor estimators were implemented in a low cost hardware architecture proposed in the paper, with the purpose of showing the inherent estimator errors and the external error factors such as noise, quantization errors and sampling clock affected by jitter. In order to test the estimation algorithms, analysis under steady-state and dynamic conditions were performed. The tests were made under the conditions specified in the IEEE Standard C37.118.1-2011 and the total vector error of the algorithms was considered as the performance index. The studied and implemented algorithms were chosen by its nature, so one is based on frequency-domain analysis making an Interpolated-Discrete Fourier Transform and the other is based on time-domain analysis, implementing frequency mixing and a low pass FIR filter.
</description>
<pubDate>Mon, 01 Jan 2018 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/90518</guid>
<dc:date>2018-01-01T00:00:00Z</dc:date>
<dc:description>This paper presents a description and performance comparison of two synchrophasor estimation algorithms proposed in the literature. The theoretical error performance is analyzed and compared with a practical implementation. Both synchrophasor estimators were implemented in a low cost hardware architecture proposed in the paper, with the purpose of showing the inherent estimator errors and the external error factors such as noise, quantization errors and sampling clock affected by jitter. In order to test the estimation algorithms, analysis under steady-state and dynamic conditions were performed. The tests were made under the conditions specified in the IEEE Standard C37.118.1-2011 and the total vector error of the algorithms was considered as the performance index. The studied and implemented algorithms were chosen by its nature, so one is based on frequency-domain analysis making an Interpolated-Discrete Fourier Transform and the other is based on time-domain analysis, implementing frequency mixing and a low pass FIR filter.</dc:description>
</item>
<item>
<title>Comparación de aceites dieléctricos minerales y vegetales en relación a la producción de gases</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/77711</link>
<description>Objeto de conferencia
Congreso Bienal de IEEE Argentina ARGENCON 2018 (Tucumán, 6 al 8 de junio de 2018)
In the manufacture of power transformers, mineral oils distilled from petroleum have traditionally been used as liquid insulation. Oil is one of the essential components for the correct operation of a power transformer. Its functions are to ensure the isolation between active parts, evacuate the heat, and protect other insulators (such as paper) from moisture. Moreover, the analysis of insulating oil provides a diagnosis of the state of the transformer without removing it from service. In recent years have begun to use dielectric oils of vegetable sources. These new oils are biodegradable; improve the cooling of the transformer and have a high fire and flash point compared to mineral oils. However, its high cost and low evaluation in service (performance), still limit its application. For mineral oils, there is a clear link between each type of fault and the gases generated. This is due to the fact that there is a large database obtained from the study of numerous cases over many years. On the contrary, the limited field data related to vegetable oil compared to mineral oils, makes the analysis of dissolved gases unreliable. Some preliminary studies attempt to determine the differences between each type of oil. This paper presents a review of the difference between the gases formed in mineral and vegetable oils as result of the most common faults in transformers.; En la producción comercial de transformadores de potencia han sido utilizados tradicionalmente aceites minerales derivados del petróleo como aislamiento líquido. El aceite es uno de los componentes esenciales para el correcto funcionamiento de un transformador de potencia. Sus funciones son garantizar el aislamiento entre partes activas, contribuir a la refrigeración, proteger de la humedad a otros aislantes (como el papel) y ofrecer la posibilidad de realizar un diagnóstico del estado de la máquina sin sacarla de servicio. En los últimos años han comenzado a difundirse aceites dieléctricos de origen vegetal. Estos nuevos aceites resultan biodegradables, mejoran la refrigeración de un transformador y tienen un alto punto de inflamación en comparación con los aceites minerales. Sin embargo, su elevado costo y su escasa evaluación en servicio (desempeño), aún limitan en cierto grado su aplicación. Para los aceites minerales existe una clara vinculación entre cada falla y la composición de gases disueltos que se originan. Esta vinculación ha quedado establecida en la base a un elevado número de casos observados a lo largo de muchos años. La limitada experiencia registrada con aceites vegetales frente a la gran base de conocimiento en los aceites minerales, por el contrario, impide que el análisis de gases disueltos pueda ser considerado en estos casos como una herramienta de diagnóstico importante. Algunos estudios preliminares intentan determinar las diferencias entre cada tipo de aceite. En este trabajo se presenta una revisión de las diferencias entre aceites de origen mineral y vegetal orientada principalmente a la formación de gases producto de las fallas más comunes en transformadores.
</description>
<pubDate>Mon, 01 Jan 2018 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/77711</guid>
<dc:date>2018-01-01T00:00:00Z</dc:date>
<dc:description>In the manufacture of power transformers, mineral oils distilled from petroleum have traditionally been used as liquid insulation. Oil is one of the essential components for the correct operation of a power transformer. Its functions are to ensure the isolation between active parts, evacuate the heat, and protect other insulators (such as paper) from moisture. Moreover, the analysis of insulating oil provides a diagnosis of the state of the transformer without removing it from service. In recent years have begun to use dielectric oils of vegetable sources. These new oils are biodegradable; improve the cooling of the transformer and have a high fire and flash point compared to mineral oils. However, its high cost and low evaluation in service (performance), still limit its application. For mineral oils, there is a clear link between each type of fault and the gases generated. This is due to the fact that there is a large database obtained from the study of numerous cases over many years. On the contrary, the limited field data related to vegetable oil compared to mineral oils, makes the analysis of dissolved gases unreliable. Some preliminary studies attempt to determine the differences between each type of oil. This paper presents a review of the difference between the gases formed in mineral and vegetable oils as result of the most common faults in transformers.

En la producción comercial de transformadores de potencia han sido utilizados tradicionalmente aceites minerales derivados del petróleo como aislamiento líquido. El aceite es uno de los componentes esenciales para el correcto funcionamiento de un transformador de potencia. Sus funciones son garantizar el aislamiento entre partes activas, contribuir a la refrigeración, proteger de la humedad a otros aislantes (como el papel) y ofrecer la posibilidad de realizar un diagnóstico del estado de la máquina sin sacarla de servicio. En los últimos años han comenzado a difundirse aceites dieléctricos de origen vegetal. Estos nuevos aceites resultan biodegradables, mejoran la refrigeración de un transformador y tienen un alto punto de inflamación en comparación con los aceites minerales. Sin embargo, su elevado costo y su escasa evaluación en servicio (desempeño), aún limitan en cierto grado su aplicación. Para los aceites minerales existe una clara vinculación entre cada falla y la composición de gases disueltos que se originan. Esta vinculación ha quedado establecida en la base a un elevado número de casos observados a lo largo de muchos años. La limitada experiencia registrada con aceites vegetales frente a la gran base de conocimiento en los aceites minerales, por el contrario, impide que el análisis de gases disueltos pueda ser considerado en estos casos como una herramienta de diagnóstico importante. Algunos estudios preliminares intentan determinar las diferencias entre cada tipo de aceite. En este trabajo se presenta una revisión de las diferencias entre aceites de origen mineral y vegetal orientada principalmente a la formación de gases producto de las fallas más comunes en transformadores.</dc:description>
</item>
<item>
<title>Sweep frequency response analysis test as tool for distribution transformers management</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/76285</link>
<description>Objeto de conferencia
25th International Conference And Exhibition On Electricity Distribution (CIRED 2019) (Madrid, 3 al 6 de junio de 2019)
Distribution transformers used in secondary substations are strongly affected during faults in low voltage grids. Transformers are expected to survive a number of short circuits without failure but, once any significant winding deformation or core damage is produced, the service life and the likelihood of surviving further short circuits is greatly reduced because of locally increased electromagnetic stresses. Given the need for diagnosing failures and quickly putting the unit back into service it is evident that a complete set of tests, as done in power transformers’ condition assessment, is not an option. The main objective of this paper is to present Sweep Frequency Response Analysis (SFRA) test as an alternative to assess the mechanical condition of distribution transformers. For this purpose, a special design of a distribution transformer was used to simulate some failure modes and improve interpretation criteria.
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/76285</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Distribution transformers used in secondary substations are strongly affected during faults in low voltage grids. Transformers are expected to survive a number of short circuits without failure but, once any significant winding deformation or core damage is produced, the service life and the likelihood of surviving further short circuits is greatly reduced because of locally increased electromagnetic stresses. Given the need for diagnosing failures and quickly putting the unit back into service it is evident that a complete set of tests, as done in power transformers’ condition assessment, is not an option. The main objective of this paper is to present Sweep Frequency Response Analysis (SFRA) test as an alternative to assess the mechanical condition of distribution transformers. For this purpose, a special design of a distribution transformer was used to simulate some failure modes and improve interpretation criteria.</dc:description>
</item>
<item>
<title>Evaluación del estado de aisladores compuestos retirados de servicio: Experiencias tendientes a determinar la expectativa de vida residual</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/75465</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do Cigré (ERIAC) (Foz do Iguaçu, Brasil, 19 al 23 de mayo de 2019)
Este trabajo describe experiencias realizadas sobre diferentes modelos de aisladores compuestos retirados de servicio, con 12 a 20 años de uso. Dichas experiencias están orientadas a determinar la expectativa de vida residual de los mencionados aisladores.&#13;
Las experiencias, realizadas se basaron en las recomendaciones del Reporte Técnico 481 de CIGRE, de diciembre de 2011. El objetivo del trabajo es ampliar el espectro de posibilidades y variantes de los programas de ensayo desarrollados en el reporte mencionado, además de contribuir a una mejor evaluación del estado de los aisladores a partir de los resultados obtenidos.
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/75465</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Este trabajo describe experiencias realizadas sobre diferentes modelos de aisladores compuestos retirados de servicio, con 12 a 20 años de uso. Dichas experiencias están orientadas a determinar la expectativa de vida residual de los mencionados aisladores.&#13;
Las experiencias, realizadas se basaron en las recomendaciones del Reporte Técnico 481 de CIGRE, de diciembre de 2011. El objetivo del trabajo es ampliar el espectro de posibilidades y variantes de los programas de ensayo desarrollados en el reporte mencionado, además de contribuir a una mejor evaluación del estado de los aisladores a partir de los resultados obtenidos.</dc:description>
</item>
<item>
<title>Efecto de la temperatura en ensayos estáticos de motor de media tensión</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/75463</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do Cigré (ERIAC) (Foz do Iguaçu, Brasil, 19 al 23 de mayo de 2019)
Los grandes motores de media tensión suelen tener como objetivo accionar los mecanismos principales y procesos críticos de una industria, por lo que es preciso establecer un programa de mantenimiento adecuado. El correcto diagnóstico de estas máquinas puede ayudar a prevenir una salida intempestiva. Esto se traduce en una reducción de los costos asociados a la pérdida de productividad y la reparación o reemplazo de la máquina afectada. En el presente trabajo se presenta un caso de estudio de un motor de media tensión, al cual se le realizaron diversos ensayos a diferentes temperaturas para obtener un diagnóstico de la condición general de su aislamiento estatórico. El objetivo de los ensayos realizados a diferentes temperaturas fue el verificar el comportamiento de los parámetros más representativos que caracterizan el aislamiento de los motores: resistencia de aislamiento, tangente delta y descargas parciales. Se presentan los fundamentos principales de las pruebas realizadas y finalmente un análisis comparativo de los resultados obtenidos en diferentes condiciones térmicas del sistema de aislamiento.
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/75463</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Los grandes motores de media tensión suelen tener como objetivo accionar los mecanismos principales y procesos críticos de una industria, por lo que es preciso establecer un programa de mantenimiento adecuado. El correcto diagnóstico de estas máquinas puede ayudar a prevenir una salida intempestiva. Esto se traduce en una reducción de los costos asociados a la pérdida de productividad y la reparación o reemplazo de la máquina afectada. En el presente trabajo se presenta un caso de estudio de un motor de media tensión, al cual se le realizaron diversos ensayos a diferentes temperaturas para obtener un diagnóstico de la condición general de su aislamiento estatórico. El objetivo de los ensayos realizados a diferentes temperaturas fue el verificar el comportamiento de los parámetros más representativos que caracterizan el aislamiento de los motores: resistencia de aislamiento, tangente delta y descargas parciales. Se presentan los fundamentos principales de las pruebas realizadas y finalmente un análisis comparativo de los resultados obtenidos en diferentes condiciones térmicas del sistema de aislamiento.</dc:description>
</item>
<item>
<title>Diagnóstico de máquinas rotantes: normalización y estado del arte actual</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/75461</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do Cigré (ERIAC) (Foz do Iguaçu, Brasil, 19 al 23 de mayo de 2019)
Considerando la importancia que revisten los procesos accionados con maquinaria rotante de potencia, resulta imperioso tener un pormenorizado conocimiento de la condición de dichas máquinas, a los fines de adoptar las medidas necesarias para optimizar la producción, evitando salidas intempestivas.&#13;
El presente trabajo tiene como objetivo presentar una recopilación del estado actual de las directrices y recomendaciones del mantenimiento eléctrico de grandes máquinas rotatorias. De esta forma, la publicación ofrecerá una guía para el diagnóstico de máquinas rotatorias tomando como referencia los principales lineamientos establecidos en normativas y documentos técnicos internacionales vigentes.
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/75461</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Considerando la importancia que revisten los procesos accionados con maquinaria rotante de potencia, resulta imperioso tener un pormenorizado conocimiento de la condición de dichas máquinas, a los fines de adoptar las medidas necesarias para optimizar la producción, evitando salidas intempestivas.&#13;
El presente trabajo tiene como objetivo presentar una recopilación del estado actual de las directrices y recomendaciones del mantenimiento eléctrico de grandes máquinas rotatorias. De esta forma, la publicación ofrecerá una guía para el diagnóstico de máquinas rotatorias tomando como referencia los principales lineamientos establecidos en normativas y documentos técnicos internacionales vigentes.</dc:description>
</item>
<item>
<title>Instrumentación virtual: voltímetro de cresta/eficaz para ensayos de alta tensión</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/75458</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do Cigré (ERIAC) (Foz do Iguaçu, Brasil, 19 al 23 de mayo de 2019)
Para los ensayos y mediciones de altas tensiones de frecuencia industrial, es necesario disponer de instrumental que, con adecuados niveles de exactitud, permitan medir los valores cresta y eficaz aplicados sobre el objeto bajo ensayo. Los criterios básicos para estas mediciones se establecen en las normas IEC 60060. &#13;
Con el avance tecnológico de los últimos años, las mediciones eléctricas se encuentran en un proceso de modernización, contemplando la implementación de instrumentos virtuales. Con ello, un sistema de medición consistiría de una placa adquisidora apropiada y de un software que cumpla los requisitos de medición necesarios. Debido a esto, están bajo estudio las normas IEC 61083-3 e IEC 61083-4 que tratan sobre el hardware y el software de medición respectivamente, para las mediciones de tensiones de frecuencia industrial en ensayos de alta tensión.&#13;
El sistema de medición de alta tensión de frecuencia industrial de 300 kV del IITREE está compuesto por un divisor de tensión capacitivo y dos voltímetros analógicos, uno de tensión eficaz y otro de tensión cresta (dividido raíz de 2). El instrumento de valor eficaz es del tipo electroestático y el de valor cresta posee un detector de valor máximo de la onda, que se convierte a corriente y finalmente es medida por un galvanómetro. Ambos poseen una indicación por haz de luz deflactada por un espejo y la cupla antagónica se obtiene con un fleje metálico calibrado. Las calibraciones y mantenimiento de dicho instrumental resultan lentos y costosos. &#13;
En el mercado convencional, fácilmente se disponen de instrumentos digitales de valor eficaz, no así de valor cresta de la onda. Por ello, se ha recurrido a la instrumentación virtual, mediante una placa adquisidora que registra la señal (tensión) y un software dedicado que realiza los cálculos correspondientes. &#13;
En el presente trabajo se describe la implementación de un nuevo sistema de medición digital virtual, indicando los requerimientos de la placa de adquisición y el desarrollo del software que realiza el cálculo del valor eficaz y cresta a partir de la señal adquirida. Además de las funciones principales de medición, se han podido desarrollar otras funciones respecto a un voltímetro convencional, como la adquisición de la forma de onda, el perfil de tensión y otros parámetros de interés establecidos por la norma. Adicionalmente se complementó con la corrección por condiciones ambientales.
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/75458</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Para los ensayos y mediciones de altas tensiones de frecuencia industrial, es necesario disponer de instrumental que, con adecuados niveles de exactitud, permitan medir los valores cresta y eficaz aplicados sobre el objeto bajo ensayo. Los criterios básicos para estas mediciones se establecen en las normas IEC 60060. &#13;
Con el avance tecnológico de los últimos años, las mediciones eléctricas se encuentran en un proceso de modernización, contemplando la implementación de instrumentos virtuales. Con ello, un sistema de medición consistiría de una placa adquisidora apropiada y de un software que cumpla los requisitos de medición necesarios. Debido a esto, están bajo estudio las normas IEC 61083-3 e IEC 61083-4 que tratan sobre el hardware y el software de medición respectivamente, para las mediciones de tensiones de frecuencia industrial en ensayos de alta tensión.&#13;
El sistema de medición de alta tensión de frecuencia industrial de 300 kV del IITREE está compuesto por un divisor de tensión capacitivo y dos voltímetros analógicos, uno de tensión eficaz y otro de tensión cresta (dividido raíz de 2). El instrumento de valor eficaz es del tipo electroestático y el de valor cresta posee un detector de valor máximo de la onda, que se convierte a corriente y finalmente es medida por un galvanómetro. Ambos poseen una indicación por haz de luz deflactada por un espejo y la cupla antagónica se obtiene con un fleje metálico calibrado. Las calibraciones y mantenimiento de dicho instrumental resultan lentos y costosos. &#13;
En el mercado convencional, fácilmente se disponen de instrumentos digitales de valor eficaz, no así de valor cresta de la onda. Por ello, se ha recurrido a la instrumentación virtual, mediante una placa adquisidora que registra la señal (tensión) y un software dedicado que realiza los cálculos correspondientes. &#13;
En el presente trabajo se describe la implementación de un nuevo sistema de medición digital virtual, indicando los requerimientos de la placa de adquisición y el desarrollo del software que realiza el cálculo del valor eficaz y cresta a partir de la señal adquirida. Además de las funciones principales de medición, se han podido desarrollar otras funciones respecto a un voltímetro convencional, como la adquisición de la forma de onda, el perfil de tensión y otros parámetros de interés establecidos por la norma. Adicionalmente se complementó con la corrección por condiciones ambientales.</dc:description>
</item>
<item>
<title>Precauciones y consideraciones para la ejecución de ensayos in situ en cables de media tensión de aislamiento XLPE</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/75455</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do Cigré (ERIAC) (Foz do Iguaçu, Brasil, 19 al 23 de mayo de 2019)
Una vez que los cables son tendidos, previo a su energización resulta importante verificar el estado del mismo, especialmente su aislamiento, ya que con ello se puede verificar la calidad del tendido. Algo similar ocurriría en el caso de un cable que, al cabo de una falla, la misma fue reparada y previo a su reposición es fundamental verificar la efectividad de dicha acción correctiva. En este sentido, los ensayos juegan un rol escencial, siendo los ensayos de tensión resistida los más comunes y fáciles de realizar. Para ello, tradicionalmente se han aplicado tensiones continuas, por su facilidad y practicidad en lo que respecta al instrumental requerido, no obstante, en el caso de los cables de aislamiento XLPE la tensión continua puede ser nociva para el estado integral del aislamiento. Las nuevas normas recomiendan la aplicación de nuevas técnicas de pruebas como VLF (tensión de baja frecuencia). Sin embargo, a partir de un relevamiento realizado, dichas técnicas no son de amplia difusión en nuestra región, en especial por las empresas distribuidoras que operan redes de MT. En el presente trabajo, se presentan las recomendaciones y requerimientos normalizados, las prácticas y metodologías que se están difundiendo entres las compañías distribuidoras. Se desarrollan los conceptos de la relación entre los árboles de agua (y eléctricos) con el fenómeno de carga atrapada y los ensayos con tensiones continuas.
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/75455</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Una vez que los cables son tendidos, previo a su energización resulta importante verificar el estado del mismo, especialmente su aislamiento, ya que con ello se puede verificar la calidad del tendido. Algo similar ocurriría en el caso de un cable que, al cabo de una falla, la misma fue reparada y previo a su reposición es fundamental verificar la efectividad de dicha acción correctiva. En este sentido, los ensayos juegan un rol escencial, siendo los ensayos de tensión resistida los más comunes y fáciles de realizar. Para ello, tradicionalmente se han aplicado tensiones continuas, por su facilidad y practicidad en lo que respecta al instrumental requerido, no obstante, en el caso de los cables de aislamiento XLPE la tensión continua puede ser nociva para el estado integral del aislamiento. Las nuevas normas recomiendan la aplicación de nuevas técnicas de pruebas como VLF (tensión de baja frecuencia). Sin embargo, a partir de un relevamiento realizado, dichas técnicas no son de amplia difusión en nuestra región, en especial por las empresas distribuidoras que operan redes de MT. En el presente trabajo, se presentan las recomendaciones y requerimientos normalizados, las prácticas y metodologías que se están difundiendo entres las compañías distribuidoras. Se desarrollan los conceptos de la relación entre los árboles de agua (y eléctricos) con el fenómeno de carga atrapada y los ensayos con tensiones continuas.</dc:description>
</item>
<item>
<title>Efectos de la condición del núcleo magnético en las respuestas del Análisis de Respuesta en Frecuencia</title>
<link>http://sedici.unlp.edu.ar:80/handle/10915/75454</link>
<description>Objeto de conferencia
XVIII Encontro Regional Ibero-Americano do Cigré (ERIAC) (Foz do Iguaçu, Brasil, 19 al 23 de mayo de 2019)
Los transformadores de potencia conforman el grupo de los activos más significativos en los sistemas eléctricos. La integridad y las adecuadas condiciones operativas de los mismos dependen de una gran cantidad de componentes internos que deben funcionar adecuadamente en su conjunto. Uno de estos componentes, de particular importancia para el buen desempeño de la unidad, es el núcleo magnético. Una manera de evaluar la condición interna del material magnético es utilizando la prueba de Análisis de Respuesta en Frecuencia (FRA), por medio de la cual es posible obtener información relevante sobre su estado mecánico. En este trabajo se compararon curvas de respuesta en frecuencia obtenidas de diferentes máquinas y ante distintas condiciones mecánicas del núcleo magnético.
</description>
<pubDate>Tue, 01 Jan 2019 00:00:00 GMT</pubDate>
<guid isPermaLink="false">http://sedici.unlp.edu.ar:80/handle/10915/75454</guid>
<dc:date>2019-01-01T00:00:00Z</dc:date>
<dc:description>Los transformadores de potencia conforman el grupo de los activos más significativos en los sistemas eléctricos. La integridad y las adecuadas condiciones operativas de los mismos dependen de una gran cantidad de componentes internos que deben funcionar adecuadamente en su conjunto. Uno de estos componentes, de particular importancia para el buen desempeño de la unidad, es el núcleo magnético. Una manera de evaluar la condición interna del material magnético es utilizando la prueba de Análisis de Respuesta en Frecuencia (FRA), por medio de la cual es posible obtener información relevante sobre su estado mecánico. En este trabajo se compararon curvas de respuesta en frecuencia obtenidas de diferentes máquinas y ante distintas condiciones mecánicas del núcleo magnético.</dc:description>