Subir material

Suba sus trabajos a SEDICI, para mejorar notoriamente su visibilidad e impacto

 

Mostrar el registro sencillo del ítem

dc.date.accessioned 2022-06-08T13:26:19Z
dc.date.available 2022-06-08T13:26:19Z
dc.date.issued 2020-03
dc.identifier.uri http://sedici.unlp.edu.ar/handle/10915/137521
dc.description.abstract An established ferric reducing antioxidant power (FRAP) assay was optimised by preparation of the derivatisation reagent in 300 mM formate instead of 300 mM acetate conditions, resulting in increased sensitivity signal to noise responses by up to five to ten times. The quantitative protocol for selective detection of antioxidants via a HPLC post column derivatisation (PCD) technique using the 300 mM formate FRAP reagent conditions was then transformed into a high-speed qualitative screening protocol by utilizing an emerging technology ‘reaction flow (RF) chromatography’. Reaction flow chromatography’s ability to screen for total antioxidant capacity with additional peak specificity/profile information of active peaks could be achieved in under 2 min. en
dc.format.extent 608-616 es
dc.language en es
dc.subject Total antioxidant capacity es
dc.subject Post column derivatisation es
dc.subject Reaction flow chromatography es
dc.subject Selective detection es
dc.subject Ferric reducing antioxidant power es
dc.title Total Antioxidant Capacity with Peak Specificity via Reaction Flow Chromatography and the Ferric Reducing Antioxidant Power Assay en
dc.type Articulo es
sedici.identifier.other doi:10.1007/s12161-019-01675-5 es
sedici.identifier.issn 1936-9751 es
sedici.identifier.issn 1936-976X es
sedici.creator.person Jones, Andy es
sedici.creator.person Acquaviva, Agustín es
sedici.creator.person Suktham, Thirada es
sedici.creator.person Dennis, Gary R. es
sedici.creator.person Shalliker, R. Andrew es
sedici.creator.person Soliven, Arianne es
sedici.subject.materias Ciencias Exactas es
sedici.subject.materias Química es
sedici.description.fulltext true es
mods.originInfo.place Laboratorio de Investigación y Desarrollo de Métodos Analíticos (LIDMA) es
sedici.subtype Articulo es
sedici.rights.license Creative Commons Attribution 4.0 International (CC BY 4.0)
sedici.rights.uri http://creativecommons.org/licenses/by/4.0/
sedici.description.peerReview peer-review es
sedici.relation.journalTitle Food Analytical Methods es
sedici.relation.journalVolumeAndIssue vol. 13, no. 3 es


Descargar archivos

Este ítem aparece en la(s) siguiente(s) colección(ones)

Creative Commons Attribution 4.0 International (CC BY 4.0) Excepto donde se diga explícitamente, este item se publica bajo la siguiente licencia Creative Commons Attribution 4.0 International (CC BY 4.0)