Subir material

Suba sus trabajos a SEDICI, para mejorar notoriamente su visibilidad e impacto

 

Mostrar el registro sencillo del ítem

dc.date.accessioned 2018-11-16T17:45:24Z
dc.date.available 2018-11-16T17:45:24Z
dc.date.issued 1999
dc.identifier.uri http://sedici.unlp.edu.ar/handle/10915/70800
dc.description.abstract An indirect enzyme linked immunosorbent assay (I-ELISA) was developed to detect antibodies to BHV-1 in serum samples. Nonidet P40-solubilized infected with BHV-I reference strain and mock-infected cell lysates were used as antigens. Serum samples were diluted 1: 64 and a commercial horse radish peroxidase-labelled rabbit anti-bovine lgG was used as second antibody. The reaction was developed using azino-dietilbenzotiazol-sulfonate (ABTS). Cut-off was determined by ratio sample (Rs). Virus neutralization (VN) test was used as a reference test over the 587 samples, 416 of them were positive by VN and 1-EL1SA, 145 were negative by both techniques, and 26 were positive by 1-EL1SA and negative by VN. Using VN as standard, the ELISA showed a relative specificity and sensibility of 100 and 84.79%, respectively. en
dc.description.abstract Se desarrolló un ELISA indirecto para el diagnóstico de VHB-1, utilizando un antígeno soluble elaborado con una cepa viral de referencia. Los sueros se emplearon en la dilución 1:64 y como segundo anticuerpo se utilizó un suero comercial anti IgG bovina conjugado con peroxidasa. La reacción fue revelada con Azino-dietilbenzotiazol-sulfonato (ABTS) y agua oxigenada. Se determinó el punto de corte de acuerdo al cociente entre las densidades ópticas de las muestras problema (Cm) y los sueros de referencia. Los resultados fueron comparados con los obtenidos por Virus Neutralización (VN). Se analizaron 587 muestras de suero bovino tomadas al azar, de las cuales 416 resultaron positivas por ELISA y VN, 145 negativas por ambas técnicas y 26 positivas por ELISA y negativas por VN. La sensibilidad y especificidad fue de 100 y 84,79% respectivamente. es
dc.format.extent 21-24 es
dc.language es es
dc.subject Herpesvirus bovino 1; diagnóstico; ELISA indirecto es
dc.subject Métodos es
dc.subject Bovine Herpesvirus 1; diagnosis; indirect ELISA en
dc.subject Herpesvirus Bovino 1 es
dc.title Desarrollo y estandarización de un ELISA indirecto para la detección de anticuerpos contra el Herpesvirus bovino tipo 1 es
dc.title.alternative Development and standardization of an indirect ELISA to detect antibodies against bovine Herpesvirus 1 en
dc.type Articulo es
sedici.identifier.other https://doi.org/10.5354/0719-5273.2010.4803
sedici.creator.person Valera, Alejandro Rafael es
sedici.creator.person Galosi, Cecilia Mónica es
sedici.creator.person Echeverría, María Gabriela es
sedici.creator.person Silvestrini, María Pía es
sedici.creator.person Romero, Jorge Roberto es
sedici.creator.person Nosetto, Edgardo Omar es
sedici.subject.materias Ciencias Veterinarias es
sedici.description.fulltext true es
mods.originInfo.place Facultad de Ciencias Veterinarias es
sedici.subtype Articulo es
sedici.rights.license Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)
sedici.rights.uri http://creativecommons.org/licenses/by-nc-nd/4.0/
sedici.description.peerReview peer-review es
sedici.relation.journalTitle Avances en Ciencias Veterinarias es
sedici.relation.journalVolumeAndIssue vol. 13, no. 1 es


Descargar archivos

Este ítem aparece en la(s) siguiente(s) colección(ones)

Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) Excepto donde se diga explícitamente, este item se publica bajo la siguiente licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)